Attach Rear Safety Cable Attachment Channel; Secure Safety Cable Spacer And Safety Cable - BIG ASS FANS Pivot 180 Installation Manual

Table of Contents

Advertisement

16

4. Attach rear safety cable attachment channel

Install the flange spacers only if the thickness of the column flange exceeds 3/8" (1 cm). The mounting holes on the
spacer are closer to one side than the other. Make sure this side is facing the column.
1. Attach the rear safety cable attachment channel to the threaded
rod assemblies with the Rear Attachment Channel Hardware as
illustrated. Torque the Nylock nuts to 40 ft·lb (54.2 N·m).
2. Hand tighten the hex nut nearest the beam clip. Mark the 12
o'clock position on both hex nuts, and then turn the outside nut 3/4
to one full turn with a 3/4" open end wrench so that it is locked into
position. Tighten the inside nut against the outside nut using a 3/4"
open end wrench.
3. Repeat on the (3) remaining threaded rod assemblies.
Rear Attachment Channel Hardware (BAF-supplied):
a. (2) 1/2" Flat Washer
b. (2) 1/2-13 Nylock Nut

5. Secure safety cable spacer and safety cable

Allow the safety cable to hang loose until the fan is installed.
Place the looped end of the safety cable around the safety cable spacer, and then attach the spacer to the channel using the Safety
Cable Spacer Hardware as shown below. Tighten to 40 ft·lb (54.2 N·m).
Safety Cable Spacer Hardware (BAF-supplied):
a. (1) 1/2-13 x 5" Hex Head Bolt
b. (2) 1/2" Flat Washer
c. (1) Safety Cable Spacer
d. (1) 1/2-13 Nylock Nut
Complete View
Safety
Safety
Cable
Cable
Spacer
PIVOT™ 180
Safety Cable Mount Installation (cont.)
WWW.BIGASSFANS.COM
©2011 DELTA T CORP.
Exploded View
Exploded View
a
b
c
b
d
ALL RIGHTS RESERVED
b
a
Tighten this nut 3/4 to
one full turn first.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents