Power requirements for fan controllers

The power requirements for Big Ass Fans controllers are shown in the specification table in the introduction. If multiple controls are
connected to one feeder circuit, the circuit required is the sum of the feeder circuit requirements listed on the chart. For example, if two
240V 3Φ controllers are connected to a single feeder circuit, that circuit needs to be rated for 20 amps. This type of installation will also
require that each fan control be installed downstream from a dedicated over-current protection device.
Mounting the wall controller
Mount the controller to a wall using a #8–#10 screw. Adhere to the following guidelines when selecting the controller location:
• Install the controller on a flat surface that is readily accessible, free from vibration, and where there is adequate distance from foreign
objects or moving equipment.
• Do not mount any controller adjacent to or above a heat source or heat-producing equipment.
• The ambient temperature must be between 14º F (-10º C) and 122º F (50º C).
• Do not expose the controller to a corrosive atmosphere, moisture, or direct sunlight.
• When mounting the controller, keep in mind that the fan should be visible from the controller.
• A minimum distance of 6" (15.2 cm) should be maintained between fan controllers.
Note: Multiple fan controllers are available as a special order only. Please contact Customer Service for more information.
PIVOT™ 180
Electrical Installation (cont.)
6.25" (159 mm)
5.95" (151 mm)
WARNING
DO NOT USE THIS
DISCONNECT TO
START AND STOP THE
FAN. PERMANENT
DAMAGE WILL
SCA M E
SCA M E
RESULT!
AUTO
FWD
RUN
REV
M
R
F
STOP
1 2 5 6
1 2 5 6
25 4 11
25 4 11
13A13B13C 14 30 16 17
13A13B13C 14 30 16 17
L1
L2
PE
U
V
W
L1
L2
L3
/T1
/T2
/T3
L3
WWW.BIGASSFANS.COM
©2011 DELTA T CORP.