CUSTOMER INFORMATION - OPERATION

Issue 3
IMPORTANT:
You
understand
these
before operating the heater.
To Open the Control Panel
Lift lightly in the centre of the lid. The control panel
lid will then open backward to an angle.
To turn the unit 'ON'
Press the ON/OFF button to operate the heater.
The ON indicator will glow green. The spark
generator will be heard before the burner ignites
and the ON indicator glows red, indicating that the
heater is alight.
When the heater warms up, the fan will
automatically start.
Note: Initially at turning 'ON' only the
front and middle burner, low, will ignite.
After 8 minutes middle burner, high and
rear burner, high will ignite. This will
occur
each
time
switched on.
If the heater does not ignite on initial use,
this may be due to air remaining in the
gas supply line. The spark generator will
only continue for 15 seconds. After this it
will be necessary to press the ON/OFF
button OFF, then ON again.
If the appliance fails to ignite after 4 attempts,
contact Rinnai as a service call may be required.
To turn the unit 'OFF'
Simply press the ON/OFF button to switch off the
heater. The ON indicator light will go out. The Fan
will continue to operate for several minutes after
the burner has gone out in order to cool the
appliance. Do not unplug the appliance while the
fan is running.
Room Temperature Adjustment
The room temperature and pre-set temperatures
can only be displayed and adjusted when the
heater is running.
Press the "" button to increase the temperature
setting or "" button to decrease the temperature
setting.
The temperatures can be preset to:
a) [L] low (about 10°C)
b) [16°C] to [26°C] in 1°C steps
c) [H] (continuously high)
When the 'Set' temperature is lower than
the current room temperature at time of
ignition, only the front burner will ignite
on the low setting. If the 'Auto Off'
function has been selected, the heater
will revert to pilots only operation after a
short time period. When ever the pilots
are lit the ON indicator will glow red.
Lock
The lock function will help to prevent accidental
operation as well as small children from altering
Royale - Freestanding - ETR
must
read
and
instructions
fully
the
appliance
is
- 2 -
the controls. To operate the lock simply press the
LOCK
button.
The
immediately and the LOCK indicator will glow.
To Deactivate the LOCK simply press the LOCK
button for 3 seconds and the LOCK indicator will
go out. The LOCK can be deactivated at any time
in this way.
During normal operation the LOCK may be
activated and all controls, other than the OFF
switch, will be locked. Deactivating the LOCK
releases the controls. If the LOCK is activated
whilst the heater is turned OFF, then all functions
will be locked. If the heater is turned OFF while the
LOCK is activated, it cannot be turned ON again
until the LOCK is deactivated.
Flame
To operate the Flame function, simply press the
FLAME button. This function will automatically
override the thermostat and set the heater to a
default Medium / High heat setting for full visual
flame effect.
Auto Off
To operate the AUTO OFF function, simply press
the AUTO OFF button.
When the AUTO OFF function is selected, the
indicator light will illuminate and the thermostat
will turn the burners down to the OFF heat setting
when the selected temperature is reached.
When the AUTO OFF function is not selected, the
indicator light will go OFF and the thermostat will
turn the burners down to the LOW heat setting
when the selected temperature is reached.
Override
This function is intended to be used to manually
override the current operation of the heater. For
example; if the heater is in standby mode (i.e.
between finishing time and starting time of a
Timer) and the OVERRIDE button is selected,
then the heater will begin to operate and heat the
room.
To operate the OVERRIDE simply press the
OVERRIDE button. The OVERRIDE indictor will
flash.
To manually deactivate the OVERRIDE simply
press
the
OVERRIDE
OVERRIDE indicator will go out, and the heater
will return to standby mode.
The heater will continue to operate on OVERRIDE
until the OVERRIDE button is pressed again, or
one of the Timers takes over the operation of the
appliance. This means that the OVERRIDE mode
will automatically drop out if a programmed
starting time is reached.
The appliance will then return to operating at
times programmed into the Timer(s).
function
is
activated
button
again.
The
Issue 3 - ©Rinnai