CUSTOMER INFORMATION - OPERATION

IMPORTANT: You must read and
understand these instructions fully
before operating the heater.
The controls are located on the lower
left hand side of the heater.
• Ignition
Press the right hand control button firmly. This
operates the built-in safety device and starts
the electronic spark. The front burner and
pilot will ignite. Check that the burner has lit
and continue to hold the button down for up to
15 seconds. The spark will continue while the
button is held down.
If the burner does not remain alight, push the
button again and release it. This will return it
to the 'OFF' position. Wait 30 seconds, then
repeat the ignition procedure.
(The ignition button must be in the "OFF"
position before attempting re-ignition).
HIGH
MED
• To adjust the heat
Press the control buttons in order from right to
left, this will ignite additional burners as shown
in diagram below.
There is no need to hold the buttons for 15
seconds when increasing the heat.
1. Ignition / Low 7.7 MJ/h (NAT)
2. Medium
14.2 MJ/h (NAT)
3. High
25 MJ/h (NAT)
IBF - Slimfire 25
• To turn the heater off
Press and release the buttons in order from
left to right until all 3 buttons are in the "OFF"
(OUT) position. The fan will stop when the
heater cools down.
Ensure all burners are extinguished.
• Fan operation
The fan will operate authomatically when the
heater warms up, and will stop when the
combustion chamber cools.
When the heater is on the 'high' setting the fan
will operate on high speed when the heater is
hot.
When the heater is on the 'low' or 'medium'
heat setting, the fan will operate on slow
speed when the heater is hot.
When the heater is on its lowest setting the fan
may turn off as the heater cools and restart
when warm again.
NOTE: If there is a power failure when
the heater is in operation the overheat
protection may shut off the gas to
protect the heater. In the event of a
power failure, turning the heater to its
IGN
~
lowest setting may allow the heater to
LOW
continue
overheating.
The fan will not work without electrical power.
The fan may continue to operate on slow
speed
extinguished until the heater cools down.
9 MJ/h (Propane)
15.8 MJ/h (Propane
25 MJ/h (Propane)
- 2 -
operating
when
the
burners
Buttons
Fan
Low
Low)
High
without
have
been
Burner pattern
Issue 5 - ©Rinnai