180 – AL CAN1 Node Lost
Yellow alarm.
Associated parameter 2.0500.680
Cause
Bus node (SAM or EMU) lost on
CAN bus 1.
181 – AL CAN2 Node Lost
Yellow alarm.
Associated parameter 2.0500.681
Cause
Bus node (SAM or EMU) lost on
CAN bus 2.
182 – AL CAN Wrong Parameters
Red alarm.
Associated parameter 2.0500.682
Cause
Incorrect parameter values
entered in data record.
183 – AL CAN No PU-Data
Red alarm.
Associated parameter 2.0500.683
Cause
A CAN mode has been selected
in which communication with the
PU data module is initialized.
However, the required PU data
module is not available or not
valid.
ZKP-Number:
Corrective action
u Check operation of nodes and cabling. Busses (CAN bus 1 and
CAN bus 2) are redundant.
ZKP-Number:
Corrective action
u Check operation of nodes and cabling. Busses (CAN bus 1 and
CAN bus 2) are redundant.
ZKP-Number:
Corrective action
u Contact Service (configuration fault).
ZKP-Number:
Corrective action
u Contact Service (configuration fault).
MS150032/02E 2012-07 | Troubleshooting | 153