MTU Gas engine8 V 4000 L62 Operating Instructions Manual page 119

Gas engine 8 v 4000 l62
Table of Contents

Advertisement

152011 – Error Missing Ring Gear Signal
Red alarm. Initiated by IC922.
Cause
Crankshaft signal for ignition
speed 182 teeth missing.
152012 – Error Missing Reset Signal
Red alarm. Initiated by IC922.
Cause
Reset signal from crankshaft is
missing.
152013 – Error Missing Camshaft Signal
Red alarm. Initiated by IC922.
Cause
Camshaft signal for ignition is
missing.
152014 – Error Number of Teeth
Red alarm. Initiated by IC922.
Cause
Incorrect number of teeth on
timing wheel detected.
152015 – Unknown Engine Appl. Code
Red alarm. Initiated by IC922.
Cause
Ignition setting is not correct.
152016 – OverSpeed Shutdown
Red alarm. Initiated by IC922.
Cause
Genset has exceeded
admissible speed.
152018 – E2PROM Checksum Error
Red alarm. Initiated by IC922.
Cause
Hardware not ready for
operation.
Corrective action
u Check sensor B13.2, check sensor clearance and cabling,
replace if necessary. Restart of ignition system required to
restart the engine.
Corrective action
u Check sensor B75, check sensor clearance and cabling, replace
if necessary. Restart of ignition system required to restart the
engine.
Corrective action
u Check sensor B1.2, check sensor clearance and cabling,
replace if necessary. Restart of ignition system required to
restart the engine.
Corrective action
1. Check timing wheel.
2. Check settings.
Corrective action
u Check setting.
Corrective action
u Restart ignition system.
Corrective action
u Restart ignition system.
MS150032/02E 2012-07 | Troubleshooting | 119

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8 v 4000 l62

Table of Contents