151051 – PWM Duty Cycle High Error
Red alarm. Initiated by TecJet.
Cause
PWM signal is beyond the valid
range.
151052 – Battery Volt Low Error
Red alarm. Initiated by TecJet.
Cause
Supply voltage has reached
minimum limit value.
151053 – FGT Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
151054 – Delta P Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
151055 – FGP Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Configured limit value was not
attained.
151056 – Battery Volt High Error
Red alarm. Initiated by TecJet.
Cause
Supply voltage has reached
maximum limit value.
151057 – FGT High Limit Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
Corrective action
1. Check cabling.
2. Check frequency.
3. Check signal.
Corrective action
1. Check supply voltage.
2. Check cabling.
Corrective action
u Restart TecJet.
Corrective action
u Restart TecJet.
Corrective action
u Check position direction of TecJet.
Corrective action
1. Check supply voltage.
2. Check cabling.
Corrective action
u Restart TecJet.