19.0.2 Cartridges

To check the C-CARD and its connector.
Internal Data Base Test
To test the Worldwide background.
C-CARD Test
To test the C-CARD. There are the possible situations:
1. if there is a C-CARD inserted in the slot and there is not a malfunction, the name of the
C-CARD zone and the message "OK" are shown.
2. if there is a C-CARD inserted in the slot, but it is a defective C-CARD, the name of the
C-CARD zone and the message "Faulty" are shown.
3. if there is not any C-CARD inserted in the slot, the message "not present" is shown.
4. if there is a User C-CARD inserted in the slot, the message USER C-CARD is shown.
C-CARD Connector
Indicates if there is a malfunction in the connector.

19.0.3 Serial Ports

If you are having problems receiving data from the position-finding instrument, this test
should help determine the problem.
Change Parameters
To change the parameters of the serial interface. This menu allows to select the Port (Signal
Source) between PORT1, PORT2, PORT3; the Baud Rate between 300, 1200, 2400, 4800,
9600, 38400, 115200; the Data Bits (Word Length) between 7 or 8, the Parity between
even, odd or none, the Stop Bits between 1 or 2. Default settings are: Port = PORT2, Baud
Rate = 4800, Data Bits = 8, Parity = none, Stop Bits = 1.
Input Data Display
To allow the GPS Chart Plotter to act as a computer terminal and display the incoming data
exactly as it is received.
If the data displayed on the screen are unrecognizable, you may have selected the wrong
input parameters for your particular receiver, for example, Baud Rate 9600 instead of Baud
Rate 4800. Check your receiver manual to be sure that you have selected the proper
parameter. If the screen is blank, you may have a broken connection, and no data is being
received or you may have connected the device to the other input port.
Use [ZOOM IN] to stop (or continue after pause) data displaying, [ENT] to show data in hex
or ASCII mode (normal or small) and [CLR] to exit.
Loop-Back Test
This is a special test done during the production phase to check the serial ports integrity.
This function is only required by STANDARD HORIZON.