STORING MACHINE

1.
Before storing machine, be certain to completely drain and
rinse tanks of all water and solution.
2.
Drain and dry the vacuum hose as well, using the drain
hose provided
3.
Store machine in a dry area in the upright position.
4. Open recovery tank cover to promote air circulation
ATTENTION: Do not expose to rain. Store indoors.
ATTENTION: If storing machine in freezing temperatures,
be sure that machine and solution system are completely
drained and dry.

TROUBLESHOOTING

SYMPTOM:
UNIT WILL NOT TURN ON:
PROBLEM:
Not plugged in.
SOLUTION:
Plug machine in proper outlet.
PROBLEM:
Circuit breaker has popped.
SOLUTION:
Reset circuit breaker. Make sure no other items are running on the same circuit as
machine. Outlet must be a 20-amp circuit.
SYMPTOM:
PUMP IS NOT RUNNING PROPERLY:
PROBLEM:
Quick disconnects are not completely locked together.
SOLUTION:
Snap quick disconnects firmly together.
PROBLEM:
The solution tank is empty.
SOLUTION:
Fill the solution tank up with a premixed liquid detergent.
PROBLEM:
Jet on upholstery tool is clogged.
SOLUTION:
Clean jet with soft wire brush or remove jet and flush clean.
PROBLEM:
Filters are clogged.
SOLUTION:
Remove filters and rinse clean with water.
PROBLEM:
Heater is blocked with hard water deposits.
SOLUTION:
Flush out heaters with Mytee Products, Inc. system maintainer solution.