Power Cable - Raymarine a Series Installation And Operation Instructions Manual

Boating equipment
Table of Contents

Advertisement

Power cable

The display is supplied with a combined power and data multi
cable, this can be extended if required.
Power cables available
Cable
Part number
R62379
1.5 m (4.9 ft) Straight
power and data cable
1.5 m (4.9 ft) Right
R70029
angled power and data
cable
Cable extension
The following restrictions apply to any extension to the power
cable:
• Cable must be of a suitable gauge for the circuit load.
• Each unit should have its own dedicated power cable wired
back to the distribution panel.
Total length (max)
Supply voltage
0–5 m (0–16.4 ft)
12 V
24 V
5–10 m (16.4–32.8 ft)
12 V
24 V
10–15 m (32.8–49.2 ft)
12 V
24 V
15–20 m (49.2–65.5 ft)
12 V
24 V
Note: These distances are for a 2 wire power cable run from the
battery to the display (approximately the distance from the battery to the
display). To calculate the round trip length, double the figure stated here.
Breakers, fuses and circuit protection
The information below is provided as guidance to help protect
your product. The example illustrations provided are for common
vessel power arrangements, if you are unsure how to provide
the correct level of protection then please consult a Raymarine
authorized dealer for support.
Fuse and breaker rating
Fuse rating
7 A in-line fuse fitted within power
cable.
The suitable fuse rating for the thermal breaker is dependent on
the number of devices you are connecting. If in doubt consult an
authorized Raymarine dealer.
Note: Your product's power cable may have an in-line fuse
already fitted, if not then you will need to add an in-line fuse to
the positive wire of your products power connection.
Distribution panel connection
It is recommended that your product is wired through your
vessel's distribution panel via a thermal breaker or fuse.
1
4
6
42
Notes
Cable gauge (AWG)
18
20
14
18
12
16
12
14
Thermal breaker rating
5 A (if only connecting one device)
5
7
D13017-1
1. Vessel power supply positive (+)
2. In-line fuse. (If your products power cable does not have a
built in fuse then an in-line fuse should be fitted.)
3. Product power cable
4. Vessel power supply negative (-)
5. * Drain wire
6. Vessel distribution panel
7. * Vessel RF ground point connection
Note: * Only applicable to products that include a drain wire
on the product's power cable.
Battery connection with RF ground
If your vessel does not have a distribution panel then your
product may be wired directly to the battery with the drain wire
connected to the vessel's RF ground point.
1
6
1. Vessel power supply positive (+)
2. Vessel power supply negative (-)
3. In-line fuse (If your products power cable does not have a
built in fuse then an in-line fuse should be fitted.)
4. * Drain wire
5. Product power cable
6. Vessel battery
7. * Vessel RF ground point connection
Note: * Only applicable to products that include a drain wire
on the product's power cable.
Battery connection with no RF ground
If your vessel does not have a distribution panel or an RF ground
point then your product may be wired directly to the battery with
the drain wire also connected to the battery's negative terminal.
1
6
1. Vessel power supply positive (+)
2. Vessel power supply negative (-)
3. In-line fuse (If your products power cable does not have a
built in fuse then an in-line fuse should be fitted.)
4. * Drain wire connected to vessel negative power supply.
5. Product power cable
6. Vessel battery
Note: * Only applicable to products that include a drain wire
on the product's power cable.
3
7
3
a Series / c Series / e Series
D13018-1
D13019-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

E seriesC series

Table of Contents