Chart 2 - System Will Not Set - Menvier Security TS400 Installation & Programming Instructions

Intruder alarm control panels
Table of Contents

Advertisement

TS400/TS410 Installation Instructions

Chart 2 - System Will Not Set

Zone LED on and
See Chart 1 on Zone
Faults
Pulse Sounder.
Tamper LED on.
Remove control
panel cover and
disable the case
tamper.
Remove wiring from
AUX TAMPER
terminals and link
with a piece of wire
If the Tamper LED
remains lit, fit link
between TMP- and
H/O -
If the Tamper LED
remains lit ,
disconnect the
battery.
If the Tamper LED
remains lit, the
control panel is
faulty.
Enter 4 digit
engineer code and
then press 3 to select
walk test mode
Deactivate all
detectors & contacts
(e.g. close doors
etc.)
If Tamper LED goes
out there is an open
circuit within the
AUX TAMPER wiring.
If tamper LED goes
out the tamper on
the external siren is
If the Tamper LED
goes out the
battery is faulty
Testing & Fault Finding
No zone LED's on
and sounder is off.
[0]
Press
to exit
Walk Test.
[HOME]
Press
[AWAY]
to part set
or full set the system.
open.
or
21