Exit Time; Entry Time; Bell Duration Time; Change Engineer's Passcode - Menvier Security TS400 Installation & Programming Instructions

Intruder alarm control panels
Table of Contents

Advertisement

Programming

Exit Time

This timer sets the delay between the user initiating
the setting procedure and the system actually
setting. This only applies when the system is
programmed to set by "Timed Exit", see "System
Options" on page 17.
To program the exit time proceed as follows:
1. Ensure that the engineer's menu is selected,
then press [4] to select Exit Time.
2. Select the required exit time by using keys [1] to
[4] to light the appropriate zone LED. When the
LED is lit the exit time will be as shown below:
Zone LED
Zone 1
Zone 2
Zone 3
Zone 4
3. When completed, press [0] to accept, a high
pitched acceptance tone will be heard and
the system returns to the engineer's menu.

Entry Time

When the entry procedure is initiated, the Entry
Timer is started. If a valid user passcode is not
entered when the timer reaches zero, a full alarm
tone is generated from the internal sounders only
and the timer is restarted. If a valid user passcode
is not entered when the timer reaches zero for the
second time the external sounder is activated.
To program the entry time proceed as follows:
1. Ensure that the engineer's menu is selected,
then press [5] to select entry time.
2. Select the required exit time by using keys [1] to
[4] to light the appropriate zone LED. When the
LED is lit the entry time will be as shown below:
Zone LED
Zone 1
Zone 2
Zone 3
Zone 4
3. When completed, press [0] to accept, a high
pitched acceptance tone will be heard and
the system returns to the engineer's menu.
16
LED On
10 Seconds
30 Seconds
1 Minute
2 Minutes
LED On
10 Seconds
30 Seconds
1 Minute
2 Minutes
TS400/TS410 Installation Instructions

Bell Duration Time

This timer controls the duration of the external
sounder when the system is triggered into a full
alarm condition.
To program the bell duration time proceed as
follows:
1. Ensure that the engineer's menu is selected,
then press [6] to select the bell duration time.
2. Select the required bell duration time by using
keys [1] to [4] to light the appropriate zone
LED. When the LED is lit the bell duration time will
be as shown below:
Zone LED
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
3. When completed, press [0] to accept, a high
pitched acceptance tone will be heard and
the system returns to the engineer's menu.

Change Engineer's Passcode

The factory default engineer's passcode is set to
[1] [2] [3] [4], but the installation engineer should
change this to their own personal 4 digit passcode
as follows:
To change the engineer's passcode proceed
as follows:
1. Ensure that the engineer's menu is selected,
then press [7] to select change engineer's
passcode.
2. Zone LEDs 1 to 4 will now light.
3. As the new passcode is entered each LED will
go out one by one. When all 4 digits have
been entered, LEDs 1 to 4 will light again and
the new passcode must be re-entered for
confirmation.
4. A high pitched tone indicates the new
passcode was accepted, a low pitched tone
indicates the passcode was not accepted. If
the passcode was not accepted repeat the
procedure again, using a different passcode.
LED On
90 Seconds
3 Minutes
10 Minute
20 Minutes
Continuous