Menvier Security TS690 Installation & Programming Manual

Menvier Security TS690 Installation & Programming Manual

Intruder alarm control panels
Table of Contents

Advertisement

TS690 & TS690ID
Intruder Alarm Control Panels
_
~
OPEN
Installation & Programming
_
~
SYSTEM OPEN
17:30
01 Jan
A
1
2
3
B
4
5
6
C
7
8
9
D
ENT
0
ESC
Sett ing the Syst em
E n t er y ou r pa s s c o de X X X X
A
1
2
3
th en l ea v e th e p r o tec t e d a re a.
Unsetting the System
Part Set
B ELL TES T
W ALK TEST
RE SET
B
G o di r e ct ly to t h e k e yp ad an d
4
5
6
en te r y ou r p as s c o d e X X X X .
Part Set
NE W CODE
CHIME
24 Hr OMIT
Resetting
C
7
8
9
E n t er y ou r pa s s c o de X X X X f o ll ow e d
Part Set
ZONE O M IT
SILENT
by E N T the n 3 . Te l eph o n e y o u r a l ar m
D
ENT
0
ESC
c o m pan y a nd fo ll o w th ei r i ns tr uc t io ns .
FULL S ET
!
Se e U se r Ma n ua l
_
_
OPEN
~
~

Engineers menu 2

Select option :-
Manual
_
_
~
~
Engineers menu 2
Select option :-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TS690 and is the answer not in the manual?

Questions and answers

Summary of Contents for Menvier Security TS690

  • Page 1: Engineers Menu

    TS690 & TS690ID Intruder Alarm Control Panels SYSTEM OPEN 17:30 01 Jan Sett ing the Syst em E n t er y ou r pa s s c o de X X X X th en l ea v e th e p r o tec t e d a re a.
  • Page 2: Table Of Contents

    TS690 & TS690ID Installation Manual Contents Overview Biscuit Connections ....16 Wiring A Biscuit to a PIR ....16 Introduction .
  • Page 3 TS690 & TS690ID Installation Manual Add/Clear ID Devices (TS690ID) ..39 Alarm Abort & Confirmation ... . . 53 Clear & Relearn ID Devices ... 39 Alarm Abort Operation .
  • Page 4: Introduction

    Each remote keypad has two sites. The TS690 system can monitor 6 zones locally detection circuits and a single switched -ve and up to 8 zones via remote keypads or LECs. All output.
  • Page 5 (DP / EOL) DCI Connection Bell output Biscuit Biscuit 30 ID zones I.D. Loop output Strobe Digi outputs 1- 5 Digi Modem (Optional) Number of Zones = 2 to 38 Outputs 1- 3 Figure 1. TS690 & TS690ID System Architecture...
  • Page 6: System Architecture

    TS690 & TS690ID Installation Manual System Architecture Specifications Control Panel Zones: Part No.: TS690 - 6 to 14 zones Output: Switched -ve @100mA TS690M - with DC6 modem Dimensions: 150(W) x 104(H) x 30(D) mm TS690ID - 2 to 38 zones...
  • Page 7: System Installation

    A B C D E A B C D E A B C D E A B C D E Control Panel Remote Network Power for Power for Power for Power for detectors detectors detectors detectors Figure 2. TS690 & TS690ID Remote Network Wiring...
  • Page 8: Id Loop Wiring (Ts690Id Only)

    System Installation TS690 & TS690ID Installation Manual ID Loop Wiring (TS690ID Only) If a different type of cable is used, the distances should be recalculated. e.g., if 7/0.4mm cable is Each ID device is connected across a two-wire ID used, a single run of 80 metres would support 30 loop.
  • Page 9: Control Panel Installation

    Mains Cable Fused Terminal Mains Entry Block 315mA Transformer Printed Circuit Board Battery Spade connection (PCB) Position for earth lead to front cover Figure 4. TS690 & TS690ID Control Panel Layout...
  • Page 10: Control Panel Pcb Layout

    (SELV) (Only Fitted on TS690) 21V A.C. from mains transformer (SELV) Telephone connections (TNV) Aux 12V & I.D. Loop (SELV) (Only Fitted on TS690ID) DC6 Digi-modem (Only fitted on the TS690M & TS690IDM) Figure 5. TS690 & TS690ID Main PCB...
  • Page 11: Connection Terminals & Indicators

    TS690 & TS690ID Installation Manual System Installation Connection Terminals & Indicators A removable nonvolatile memory (NVM) Connection terminals on the TS690 / TS690ID are device that stores all system program described as ether “Safety Extra-Low Voltage” parameters and the 700 log events.
  • Page 12: Mains Connection

    Battery Connection Ward Sounder Control. A 7Ah battery must be fitted to the system to allow This facility is not available for TS690 and it to function during a mains fail condition. The TS690ID systems. TS690 & TS690ID is equipped with a “Battery Keys 1 and 3 PA Enable Protection”...
  • Page 13: Installation Procedure

    TS690 & TS690ID Installation Manual System Installation Network Connections & O/P. Installation Procedure. Terminals A to E are used to connect the Always ensure that all power (mains and remote keypad to the control panel battery) is removed before making any netw ork .
  • Page 14: Keypad Loudspeaker Connections

    System Installation TS690 & TS690ID Installation Manual TS700 LEC Installation 5. Set the “ENT KEY DISABLE” jumper link to the required position. The TS700 LEC (Local Expansion Card) is connected to the “Remote Network” and provides 6. Set the “WARD SOUNDER CONTROL” jumper link two additional programmable detection circuits to the required position.
  • Page 15: Wiring Detection Circuits

    TS690 & TS690ID Installation Manual System Installation 4. Connect “Remote Network” cables and Normally open devices such as pressure pads detection circuit cables to the appropriate and exit terminator buttons are connected between the zone and tamper terminals. terminals, see Figure 10 If the detection circuit is not used links can be 5.
  • Page 16: Wiring Id Biscuits

    System Installation TS690 & TS690ID Installation Manual 500 metres or 100 Ohms When the tamper switch is opened, the ID biscuit becomes off line and a tamper alarm is 4K7 = Yellow, Violet, Red 2K2 = Red, Red, Red generated by the control panel. If the alarm...
  • Page 17: Wiring A Biscuit To A Panic Button

    TS690 & TS690ID Installation Manual System Installation External Sounder Connections Wiring a Biscuit to a Panic Button The figure below shows typical wiring configuration The following terminals have been provided to for a standard panic button. allow connections to an external sounder:...
  • Page 18: Extension Loudspeakers

    System Installation TS690 & TS690ID Installation Manual Extension Loudspeakers REM RESET If the system is programmed for “Engineer Reset”, Up to two extension loudspeakers can be then after a full alarm the system will require connected across the [SPK+] and [H/O-] terminals resetting, normally this is done by the engineer or on the control panel PCB.
  • Page 19: Application

    TS690 & TS690ID Installation Manual System Installation Application Please ensure that cabling to the The DC6 digital communicator/modem is suitable telephone line connections (TNV) are for connection to the following types of telephone routed well away from the detection line:...
  • Page 20: Installation

    System Installation TS690 & TS690ID Installation Manual DC54 & DC58M Installation Installation A plug-on digital communicator DC54, DC58 or For your safety, installation of the DC6 DC58M may be fitted inside the control panel to MUST be carried out in the sequence...
  • Page 21: Connecting A Printer

    System Installation Connecting a Printer Using the CPA6 Printer The TS690 and TS690ID supports two type of 6. Plug the CPA6 printer directly on to the PRINTER printers, the CPA6 printer (no longer available) and plug (JP1) on the main control panel PCB.
  • Page 22: Pre Power-Up Checks

    System Installation TS690 & TS690ID Installation Manual +ve O/P Aux 12 V Relay available from Relay available from Diode (IN4001) Diode (IN4001) (Programmed as Alarm / Bell / etc) RS components RS components P/No. 351-982. P/No. 351-982. Capable of switching...
  • Page 23: Initial Power-Up

    TS690 & TS690ID Installation Manual System Installation Initial Power-Up 3. With the ID loop still disconnected from the control panel, use a DVM to measure the To power the system for the first time: resistance between the following cores and 1.
  • Page 24: Nvm Defaults

    System Installation TS690 & TS690ID Installation Manual NVM Defaults Section Option Default Section Option Default Rem Reset User 00 Engineer 1234 Algorithm User Codes User 01 Master 5678 00: Bell is an SAB Panel Output 1 Walk Test 01: User 1 Limited...
  • Page 25: Introduction

    TS690 & TS690ID Installation Manual Engineer’s Menu 1 Engineer’s Menu 1 Enter Engineer's Introduction Passcode Engineers menu 1 is the first of two engineers 1 2 3 4 menus, which is selected when the engineer’s passcode is entered. The engineer may leave Engineers menu 1 “Engineer menu 1"...
  • Page 26: Panel Outputs

    Engineer’s Menu 1 TS690 & TS690ID Installation Manual Panel Outputs [1.1] Digicom Channels [1.3] Outputs 1-3 on the control panel and remote The 8 plug-on digicom channels can be keypad outputs 5-8 can be programmed to any programmed to any of the output types shown on of the output types shown on pages 26 to 29.
  • Page 27 TS690 & TS690ID Installation Manual Engineer’s Menu 1 Type/Description Type/Description 004 Walk Test 017 Part Set B Selected Activates when the "Walk Test" option is Activates when "Part Set B" is selected. selected and deactivates when the "Walk Test" Deactivates when the system is unset.
  • Page 28 Engineer’s Menu 1 TS690 & TS690ID Installation Manual Type/Description Type/Description 032 Duress Alarm 044 General Fault Activates when a duress passcode is entered Activates during battery fault or when the and deactivates when the duress alarm is system is prevented from being set.
  • Page 29: Program Circuits

    Program Circuits [1.4] timer. The TS690 can monitor up to 14 detection circuits, 8 Exit Terminator whereas the TS690ID can monitor up to 38 A circuit that is normally connected to a push detection circuits.
  • Page 30: Circuit Attributes

    Engineer’s Menu 1 TS690 & TS690ID Installation Manual [7] Inverted - Inverts the operation of the The “Omit” attribute can only be assigned to keyswitch. Night, 24hr, and Auxiliary circuit types. If the “Keyswitch” is not assigned to any of the...
  • Page 31: System Timers

    TS690 & TS690ID Installation Manual Engineer’s Menu 1 are still in an alarm condition are isolated until Starburst they change to a healthy condition. This Engineers menu 1 ENGR 1 - E1 - counter controls the number of times that a Select Options :- "circuit"...
  • Page 32 Engineer’s Menu 1 TS690 & TS690ID Installation Manual when alarm confirmation is disabled, and has 06 Bell Duration This controls the duration of the external no effect when alarm confirmation is enabled. bell/sounder. If the timer is set to 199 the bell This timer has a working range of 000-199 output is continuous.
  • Page 33: Setting Modes

    TS690 & TS690ID Installation Manual Engineer’s Menu 1 19 Test Call Starburst If the system is fitted with a DC6, it is possible for Engineers menu 1 ENGR 1 - E1 - the control panel to make the DC6 send a Select Options :- timed test call to the central station.
  • Page 34: Do System Print

    Engineer’s Menu 1 TS690 & TS690ID Installation Manual Starburst To set the system the user first enters their Engineers menu 1 access code at a keypad or operates a ENGR 1 - E1 - Select Options :- keyswitch. The control unit starts the exit tone.
  • Page 35: Remote Reset Algorithm

    TS690 & TS690ID Installation Manual Engineer’s Menu 1 When programmed as “Yes” fire alarm Remote Reset Algorithm [1.8] activations are signalled to the ARC at all When the system is programmed for “Engineer times. When programmed as “No” fire alarm Reset”...
  • Page 36 Engineer’s Menu 1 TS690 & TS690ID Installation Manual 10 Tamp user reset 18 Invert Output 1 When programmed as “Yes", tamper alarms When programmed as “Yes” panel output 1 is can be reset by the user. When programmed normal. When programmed as “No” panel as ”No", tamper alarms can only be reset by...
  • Page 37 TS690 & TS690ID Installation Manual Engineer’s Menu 1 25 Answer Phone Def 30 Sounder on Confirm When programmed as “Yes”, the plug-on When programmed as “Yes” the control unit digi-modem will only answer incoming calls activates the internal sounders after a after a second attempt.
  • Page 38 Engineer’s Menu 1 TS690 & TS690ID Installation Manual 34 Entry Keypad Lock If you program Confirmation After Entry When programmed as “Yes” then users cannot as “No” then the setting of this option has unset the system from a keypad during entry.
  • Page 39: Go To User Menu 1

    TS690 & TS690ID Installation Manual Engineer’s Menu 1 Go to User Menu 1 [1.0] Add/Clear ID Devices (TS690ID) [1.A] This option allows the engineer to access “User This option allows the engineer to add and remove menu 1", the flowchart below shows the options ID devices from the system.
  • Page 40: View Location Text (Lcd Only)

    Engineer’s Menu 1 TS690 & TS690ID Installation Manual Starburst Starburst Engineers menu 1 ENGR 1 - E1 - Engineers menu 1 Select Option :- ENGR 1 - E1 - Select Options :- ID Devices >HHHHHHHHAAHH... 01 - 15 USE 16x2...
  • Page 41: Engineer's Menu 2

    TS690 & TS690ID Installation Manual Engineer's Menu 2 Engineer's Menu 2 Introduction Engineers menu 1 Engineer's menu 2 is selected by pressing the [ENT] Select Option :- key whilst Engineer's menu 1 is selected. Each menu option can be selected by pressing the relevant “Hot key”.
  • Page 42: View Circuits

    Engineer's Menu 2 TS690 & TS690ID Installation Manual View Circuits [2.1] Set System Time [2.2] Each detection circuit may be viewed to The system time is displayed in a 24hr format on all ascertain its status. The circuit status conditions...
  • Page 43: Change Passcode

    TS690 & TS690ID Installation Manual Engineer's Menu 2 Change Passcode [2.4] Alter Shunt Group [2.6] This option allows the engineer to change their Circuits can be assigned to the shunt group. The passcode. The default passcode is 1234 but the...
  • Page 44: Configure Part Sets

    [2.8] View System Log [2.9] The TS690 and TS690ID can be configured to have The engineer can use this option to view the up to three parts set modes (Part Set A, Part Set B system log. The [A] and [C] keys allow you to scroll and Part Set C).
  • Page 45: Log Event Codes

    TS690 & TS690ID Installation Manual Engineer's Menu 2 Log Event Codes Starburst Description A.C. OFF AC OFF Mains power removed. A.C. ON AC RESTORED Mains power restored ALM SENT ACTION ALARM Alarm activated when system is part-set. ALARM 01-38 CA. 0 1-38 ALARM 01-38 Full alarm from circuit (01-38).
  • Page 46: Log Event Codes

    Engineer's Menu 2 TS690 & TS690ID Installation Manual Log Event Codes Starburst Description LID TAMP PANEL LID TAMPER Control panel lid removed. P.SET A/B/C PS. A /B/C PART SET A/B/C System Part-Set using one of the A, B, or C buttons.
  • Page 47: Custom Text Menu (Lcd Only)

    TS690 & TS690ID Installation Manual Engineer's Menu 2 LCD Only Starburst Engineers menu 2 Select Option :- Engineers menu 2 ENGR 2 - E2 - Select Option :- 1-CCT, 2-Banner 3-Location Call back No. Call Number 1 CALL NO.1 No. 1 Tel No.
  • Page 48: Modem Password

    Engineer's Menu 2 TS690 & TS690ID Installation Manual This option allows the Modem site number to be LCD Only programmed. The “Modem Site No.” is a 4 digit Engineers menu 2 number that is used as a site reference. When Select Option :- using the “Lineload”...
  • Page 49: Digicom Tests

    TS690 & TS690ID Installation Manual Engineer's Menu 2 LCD Only Digicom Tests Engineers menu 2 This option allows the engineer to test each Select Option :- channel on the plug-on digi-modem (DC6) and the five digi outputs on the main PCB.
  • Page 50: Text Editing Keys

    The TS790.STAR remote keypad is capable of displaying up to eight characters of text when it is keypad function as shown below: connected to the TS690/TS690ID control panels. However the text can only be entered using a TS900 LCD remote keypad or via Lineload 0 (Zero) software.
  • Page 51: Appendices

    TS690 & TS690ID Installation Manual Appendices Appendices Contact ID Extended Reporting Contact ID extended reporting is a new format Code Description which when used with the DC6 can be used to EF Test Call report circuit ID data, user ID etc. The central...
  • Page 52 Appendices TS690 & TS690ID Installation Manual Kitchen Dining Room Hall Garage Lounge Key: Passive Infra-Red Detector Bathroom Magnetic Contact Bedroom 2 Remote Keypad Control Panel Landing Bedroom 1 Bedroom 3 Figure 27. A Typical 3 Bedroom House...
  • Page 53: Part-Set Application Example

    Part-Set Application Example Alarm Abort & Confirmation This application example shows how to configure Both the TS690 and TS690ID support “Alarm Abort” the part set buttons to set different areas of a 3 and “Sequential Confirmation”. The alarm abort bedroom house.
  • Page 54: Setup New Users

    Setup New Users company or by making the first two digits of The TS690 and TS690ID allows up to 15 users to the passcode the same. operate the alarm system, each user is assigned a user type and 4 digit passcode.
  • Page 55: Quick Reference Engineers Menus

    TS690 & TS690ID Installation Manual Appendices Quick Reference Engineers Menus Engineers Menu 1 Options Page Options Page System Configuration Program Panel Outputs 1 = Panel Output 1 (relay) 00 = Bell is an SAB Bell is an SCB 2 = Panel Output 2 (-ve)
  • Page 56: Output Types

    Appendices TS690 & TS690ID Installation Manual Quick Reference Engineers Menus Engineers Menu 2 Output Types Options Page Output Type Output Type 000 Bell On 031 Exit View Circuits A = Scroll Next Circuit 001 Strobe On 032 Duress Alarm C = Scroll Previous Circuit...
  • Page 57: Quick Reference User Menus

    TS690 & TS690ID Installation Manual Appendices Quick Reference User Menus User Menu 1 User Menu 2 Options Options Bell Test View Circuits A = Scroll Next Circuit Walk Test C = Scroll Previous Circuit Remote Reset Set System Time Enter Reply code + ENT Enter time e.g.
  • Page 58 Notes...
  • Page 59 TS690 & TS690ID Installation Manual Notes...
  • Page 60 Appendices TS690 & TS690ID Installation Manual Cooper Security Ltd, Security House, Vantage Point Business Village, Mitcheldean, Gloucestershire, GL17 0SZ. England Product Support Tel: +44 (0)1594 545556 Available between; 08:15 and 17:00, Monday to Thursday. 08:15 and 12:45 Friday. Emergency service only between 12:45 and 17:00 Friday.