en | Encoders / Decoders page
Recording format
Select a format for audio recording.
G.711: default value.
L16: Select L16 if you want better audio quality with higher sampling rates. This requires
approximately eight times the G.711 bandwidth.
18.19

Relay page

This function allows you to configure the switching behavior of the relay outputs.
You can configure the switching behavior of the relay outputs. For each relay, you can specify
an open switch relay (normally closed contact) or a closed switch relay (normally open
contact).
You can also specify whether an output should operate as a bistable or monostable relay. In
bistable mode, the triggered state of the relay is maintained. In monostable mode, you can set
the time after which the relay returns to the idle state.
You can select different events that automatically activate an output. It is possible, for
example, to turn on a floodlight by triggering a motion alarm and then turning the light off
again when the alarm has stopped.
Idle state
Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is
to operate as an NC contact.
Operating mode
Select an operating mode for the relay.
For example, if you want an alarm-activated lamp to stay on after the alarm ends, select the
Bistable entry. If you wish an alarm-activated siren to sound for ten seconds, select the 10 s
entry.
Relay follows
If required, select a specific event that will trigger the relay. The following events are possible
triggers:
Off: Relay is not triggered by events
Connection: Trigger whenever a connection is made
Video alarm: Trigger by interruption of the video signal at the corresponding input
Motion alarm: Trigger by motion alarm at the corresponding input, as configured on the VCA
page.
Local input: Trigger by the corresponding external alarm input
Remote input: Trigger by remote station's corresponding switching contact (only if a
connection exists)
Note:
The numbers in the lists of selectable events relate to the corresponding connections on the
device, Video alarm 1, for example to the Video In 1 connection.
Trigger relay
Click the relay button to trigger the relay manually (for example, for testing purposes or to
activate a door opener).
The relay button displays the state of each relay.
Red: Relay is activated.
Blue: Relay is not activated.