en | Devices page
17.21.2

SNMP Trap Receiver page

Main window >
Allows you to select devices for monitoring and to select SNMPtrapOIDs that trigger an event
for the selected device when they are received.
Notice!
i
You must enter the IP address of the Bosch Video Management System Management Server
as the trap receiver in your devices that you want to monitor.
SNMP Trap Sending Devices:
Allows you to enter a range of IP addresses of the monitored network devices. To monitor a
single device enter the corresponding IP address in the Range From cell.
Be careful when changing these addresses. Entering a wrong address stops network
monitoring of this device.
SNMP Trap Filter Rules:
Allows you to enter OIDs and corresponding values. You can use wildcards as * and ? to
enhance the filter range. If you enter OIDs and values in more than one row, these filter rules
must match simultaneously to trigger an event. In both columns, you can enter a regular
expression in {}. If there are characters outside the brackets, the regular expression is not
evaluated.
Show Trap Logger Tool
Click to display the SNMP Trap Logger dialog box for tracing SNMP trap OIDs.
17.21.3

SNMP Trap Logger dialog box

Main window >
Trap Receiver > Click Show Trap Logger Tool
Allows you to trace SNMPtrapOIDs. You can receive traps from all devices in your network or
only from selected ones. You can filter the traps to be received and you can add OIDs and
values of selected traps to the SNMP Trap Filter Rules: table.
Start/Pause
Click to start or stop a tracing process.
Only Traps From Sender
Enter the IP address or DNS name of a device. Only traps from this device are traced.
Only Traps Containing
Enter a string a trap can contain. You can use * and ? as wildcards. Strings in {} are treated as
regular expressions. Only traps containing such a string are traced.
Received Traps
Displays the traps that are received by a tracing process.
Click to remove all entries in the Received Traps field.