Engineer's Menu 2

View Circuits

Each detection circuit may be viewed to
ascertain its status. The circuit status conditions
and resistance are shown below:
Status
Response
Healthy
None
Active
Alarm
Tamper
Tamper
Shorted
Alarm

Engineers menu 2

Select Option :-

Circuit text
Front Door
CCT 01 Heathly
Circuit No. &
status
Enter circuit No.
Back Door
CCT 10 Healthy
A
= Next Circuit
C
= Previous Circuit
ESC
Circuit text
Back Door
CCT 10 is 2K2Ω
Circuit No. &
resistance
View Circuits Flowchart
36
Normal
Min.
54 Ω
2.2 KΩ
6.9 KΩ
4.1 KΩ
54 KΩ
0 Ω
0 Ω
LCD
1
e.g. 10
B
= Diagnostics (LCD Only)
TS690
ESC
[2.1]

Set System Time

The system time is displayed in a 24hr format on all
remote keypads and is also used to time stamp
events in the system event log.
Max.
4.1KΩ
54 KΩ
53 Ω

Set System Date

The system date is displayed in a day/date/month
format on LCD remote keypads. it is also used to
provide date stamps for events in the system log.
TS590 Installation Manual
LCD
Engineers menu 2
Select Option :-
2
Set Clock > ----
Enter time
e.g. 1605
New time
Set Clock > 1605

ENT

Set System Time Flowchart
LCD
Engineers menu 2
Select Option :-
3
Set Date > ----
Enter date
e.g. 2804
New date
Set Date > 2804
ENT
Set System Date Flowchart