Menvier Security TS590 Installation & Programming Manual page 32

Intruder alarm control panels
Table of Contents

Advertisement

Engineer's Menu 1
24 Monitor off hook
When programmed as "Yes", the plug-on
digicom will monitor the telephone line for
off-hook conditions (high security line
monitoring). When programmed as "No", the
plug-on digicom will only monitor the
telephone line for line cut conditions (low
security). (Default: No)
25 Answer Phone Def
When programmed as "Yes", the plug-on
digi-modem will only answer incoming calls
after a second attempt. When programmed
as "No", the plug-on digi-modem will answer
incoming calls after the modem ring counter
has expired. (Default: No)
29 Keypad PA Silent
When programmed as "Yes", pressing 1 & 3 on
the remote keypad will generate a silent PA
alarm. When programmed as "No", pressing 1
& 3 on the remote keypad will generate an
audible PA alarm. (Default: No)
30 Sounder on Confirm
When programmed as "Yes" the control unit
activates the internal sounders after a
confirmed alarm and any programmed bell
delay. When programmed as "No" the control
unit starts the internal sounders immediately
after an unconfirmed alarm. (Default = No)
31 Bells on Confirm
When programmed as "Yes" the control unit
activates the external sounders after a
confirmed alarm and any programmed bell
delay. When programmed as "No" the control
unit activates the external bell immediately
after an unconfirmed alarm. (Default = No)
32 Confirmation After Entry
When programmed as "Yes" the control unit
sends a confirmed alarm if the intruder
activates one or two separate zones after the
entry timer expires. To select between one or
two zones use "36 Entry conf 2 cct" When
programmed as "No" the control unit disables
alarm confirmation when a user starts the entry
timer. Use the "No" option to comply with
DD243:2002 paras 6.4.2, 6.4.3, 6.4.4 and
6.4.6.
(Default = No)
32
33 Confirmation On
When programmed as "Yes" then the Digicom
reports a Channel 3 (005 Intruder) for an
intruder alarm as normal. If a subsequent zone
is triggered within the same set period then the
Digicom reports Channel 7 (011 Confirmed
Alarm). The ARC operator can now inform the
appropriate police authority that the alarm is
confirmed and that this is likely to be a real
break in and not a false alarm.
When programmed as "No" then the control
panel disables Alarm Confirmation and any
Alarm Confirm outputs.
(Default = Yes)
34 Entry Keypad Lock
When programmed as "Yes" then users cannot
unset the system from a keypad during entry.
Program this option as "Yes" if you are installing
a DD243:2002 compliant system and the user
must unset the system with a proximity
detector ("Portable ACE"). The user must
employ a proximity tag to disarm the system
during the entry period.
When programmed as "No" then users can
unset the system from a keypad during entry.
+
If your make Pset Com. Dly (Eng 1.5.03) =
199 then users can unset the system
from a keypad when the system is
part-set.
(Default = No)
35 Tamp as Burg
DD243: 2002 states that alarm signals and
confirmation signals must be transmitted using
certain codes. In some cases these codes do
not conform to Cooper Security Ltd's
implementation of the CID standard. This
option allows you to program the control unit to
send tampers as alarm.
When programmed as "Yes" then the control
unit sends tampers to the ARC as Intruder
Alarms (CID 130). In Fast Format the control unit
transfers the Digicom Tamper output (default
output 8) to the Digicom Alarm output (default
output 3).
When programmed as "No" the control unit
sends all messages as specified in Report
Mode.
(Default = No)