Setup New Users

The TS590 allows up to 15 users to operate the
alarm system, each user is assigned a user type
and 4 digit passcode. User 01 is the master user
which has a default setting of 5678.

User Types

The following user types are available:
Master
User 01-15 can be programmed as the type
"Master". If the installation company has
programmed the master user for full access, they
will have access to all user menus and options. If
the installation company has programmed the
master user for limited access, they will NOT have
access to "User menu 2" options 6 and 8.
Standard
Users 02-15 can be programmed as the type
"Standard". This user type can set and unset the
alarm system and access "User menu 1".
Holiday
Users 02-15 can be programmed as the type
"Holiday". This user type can set and unset the
alarm system and access "User menu 1".
However, the passcode is automatically deleted
from the system when a master user passcode is
used to unset the alarm system. Normally the
master user would assign this passcode type a
temporary user whilst they are away on holiday.
Set Only
Users 02-15 can be programmed as "Set Only".
This user type allows the alarm system to be set
and access to "User menu 1".
Reset Only
Users 02-15 can be programmed as "Reset Only".
This user type allows 24hr alarms to be reset and
access to "User menu 1" option 1 to 7 and 9.
Duress
Users 02-15 can be programmed as "Duress".
When this user type is entered a silent "Panic Alarm"
(i.e., Bell and sounders not triggered) is transmitted
to the central station via the telephone line and
remote signalling device (if fitted). The user will still
be able to set and unset the alarm system and
+
access "User menu 1".
All other user code types will generate a
"Duress" alarm if the passcode is entered
with the first two digits reversed (e.g., for a
standard passcode of 2580 enter 5280 to
generate a "Duress" alarm). If required, this
48
feature can be disabled by the installation
company or by making the first two digits of
the passcode the same.
PA Code
Users 02-15 can be programmed as "PA Code".
When this user type is entered a "Panic Alarm"' is
transmitted to the central station via the telephone
line and remote signalling device (if fitted). The
external sounder(s) and strobe light(s) are also
activated.
Shunt
Users 02-15 can be programmed as "Shunt".
When this user type is entered the circuits assigned
to the shunt group are isolated. When the
passcode is re-entered the circuits assigned to the
shunt group are reinstated.
Enter master user (5678)
User menu 2
Select Option :-
Setup users
User No. >--
Alter user type
Standard
Enter user type:
1
= Master
2
= Standard
3
= Holiday
4
= Set Only
e.g. 1 for Master
Change pass code
New code > -----
Enter New passcode
Change pass code
New code > 2589