Installation Procedure - Menvier Security TS590 Installation & Programming Manual

Intruder alarm control panels
Table of Contents

Advertisement

System Installation
Display Module
10
Figure 6. LCD Remote Keypad PCB Layout
1
Display Module
10
Figure 7. NETLCD PCB Layout
+

Installation Procedure.

Always ensure that all power (mains and
battery) is removed before making any
connections to the remote keypad.
1. Separate the cover and base by using a
screwdriver to push 2 of the clips (top or
bottom) inward from the base indents, then lift
the cover assembly, noting that the PCB is fixed
to the under side of the cover.
2. Hold the base in position (keyhole to the top)
and mark the three securing holes, drill and
12
LED MIMIC
3
1
I/D
2
4
3
Selector
4
ENG
REMOTE
I/D
5
6
A B C D E
O/P
SPK
-
+
8 8 9
8
7
2
LED MIMIC
3
1
I/D
2
4
3
Selector
4
ENG
REMOTE
I/D
5
6
A B C D E
O/P
SPK
-
+
8 8 9
8
7
plug the wall as required. Pass all the cables
into the base via the cable entry points as
appropriate and secure the base to the wall.
3. Connect "Remote Network" and detection
circuit cables to the appropriate terminals.
4. Set the I/D selector jumper link to the required
position:
NETLCD, TS700 LEC and LEC6
I/D Selector
Circuit A
1
07
2
09
3
11
4
13
ENG/NULL
N/A
LCD Remote Keypad
I/D Selector
1
2
3
4
ENG/NULL
l
No two remote keypads or LECs should
have the same I/D.
l
If the I/D is set to "ENG" the remote keypad
will function as an Engineer's keypad
allowing it to be plugged onto the control
panel so that system programming and
testing can be carried out, see Engineer's
Keypad.
5. Set the "ENT KEY DISABLE" jumper link to the
required position.
6. Set the "WARD SOUNDER CONTROL" jumper link
to the required position.
7. Finally clip the remote keypad cover onto the
base being careful not to trap any cables or to
obstruct the tamper switch.
TS590 Installation Manual
Panel
Circuit B
Output
08
5
10
6
12
7
14
8
N/A
N/A
Panel Output
5
6
7
8
N/A