Programming
Key
0
Bell output is set for SAB
1
Disable Master User from menu 2 options 4-9
2
Fire Signalled when Unset/Part Set/Full Set
3
24hour circuits silent when Unset
4
Bell is instant when Part Set
5
Alarm output (05) cleared when system is unset
6
Setting inhibited with line fault/no mains power
7
System reset by User or Engineer
8
Continuous Entry and Exit tones
9
Engr & Remote Reset code to gain access to E1/E2 Engr code gains access to E1 and E2 menus

Engineer's Menu 2

This menu is selected by pressing the [ENT] key whilst "Engineers menu 1" is selected. There are ten
programming options within this menu, which can be selected in any order. The engineer can
leave this menu and return to "Engineers Menu 1" by pressing the [ESC] key.

View Circuits

This option allows the engineer to view the status of each detection circuit. The circuit status
conditions are H=Healthy, A=Active, S=Shorted or T=Tamper.
1.
Ensure that "Engineer Menu 2" is selected.
2.
Press 1 to select the View Circuits option.
3.
The circuit status will be displayed.
4.
Select circuits either by entering the number or by pressing [ to
scroll through the circuits.
5.
Press ] to abandon and return to "Engineer Menu 2".

Change Time

The system clock may be changed using 24 hour clock format.
1.
Ensure that "Engineer Menu 2" is selected.
2.
Press 2 to select the Change Time option.
3.
Enter the time in 24 hour notation (e.g., 1805).
4.
Press [ to accept.
22
YES
Table 6. System Configuration options
TS700 Installation Manual
Bell output is set for SCB
Master user has access to all options in menu 2
Fire signalled only when full Set
24hour circuits audible when Unset
Bell is delayed when Part Set (30 secs)
Alarm output cleared when system is reset
Setting allowed with line fault/no mains power
System reset by Engineer or Remote Reset
Rising Entry and Exit tones
NO
03-H
Circuit 03 is Healthy.
03-A
Circuit 03 is Active.
----
Enter time in 24 hour format.
1805
Time entered 1805 (6:05 pm.)