Setting Modes; Do System Print - Menvier Security TS590 Installation & Programming Manual

Intruder alarm control panels
Table of Contents

Advertisement

TS590 Installation Manual
014 the test call will be signalled at 14.00
(2.00pm). This timer has a working range of 000
- 023. (Default: 003)
Timer Type
Timer value
System Timers Flowchart

Setting Modes

The setting mode for full set and each part set can
be configured to the following setting modes:
1 Final Exit
The system will set when the "Final Exit" circuit is
activated and after the "Settle Time" has
expired.
2 Exit Terminator
The system will set when the "Final Exit" circuit is
activated, the "Exit Terminator" button is
pressed and after the "Settle Time" has
expired.
3 Timed Exit
The system will set when the "Exit Time" has
expired or if the "Exit terminator" button is
pressed and the "Settle Time" has expired.
4 Instant
The system will set instantly.
5 Deferred
As timed exit, however, if any circuits are
activated during the exit procedure the exit
timer is restarted.
LCD
Engineers menu 1
Select Options :-
5
System Timers
Enter Number >--
Enter timer No.
e.g. 04 for exit time
ENT
System Timers
Exit Time... 030
Enter new timer value
e.g. 045
System Timers
Exit Time... 045
ENT
[1.6]

Do System Print

If a printer is connected to the control panel a print
out of all system parameters can be obtained.
Engineer's Menu 1
LCD
Engineers menu 1
Select Options :-
6
Setting Mode ?
Enter Group > -
Enter group:
0
= Full Set
A
= Part Set A
B
= Part Set B
C
= Part Set C
e.g. 0 for full set
Full Set
by Final Exit
Set Mode
Select Set Mode:
1
= Final Exit
2
= Exit Terminator
3
= Timed Exit
4
= Instant
5
= Deferred
6
= Lockset
e.g. 3 for timed exit
Full Set
by Timed Exit
ENT
Setting Modes Flowchart
LCD
Engineers menu 1
Select Options :-
7
System Print Out
Line Number 001
System Print Flowchart
[1.7]
29