Go To User Menu 1; View Location Text; Relearn Hardware - Menvier Security TS590 Installation & Programming Manual

Intruder alarm control panels
Table of Contents

Advertisement

Engineer's Menu 1

Go to User Menu 1

This option allows the engineer to access "User
menu 1", the flowchart below shows the options
within "User menu 1", for full details refer to the
"Operators Manual".
Engineers menu 1
Select Option :-
0
User menu 1
Select Option :-
1
Bell Test
2
Walk Test
Remote
3
Reset
Change
4
code
Enable
5
Chime
Omit Shunt
6
Group
Omit
7
Circuits
8
Silent Set
0
Full Set
A
Part Set A
B
Part Set B
C
Part Set C
ESC
User Menu 1 Flowchart
34
[1.0]
ESC
Sounder. ON > 08
Press ESC to end
Walk Test
Press ESC to end
Remote Reset
Quote > 6846
Change passcode
New code > ----
Chime ccts are
Enabled
CCTS ISOLATED
08:30 Sun 28 Apr
Omit Circuits
Enter CCT No.>--
Silent Set ?
Enter Group > -
Please Exit Now.
Time left > 029
Please Exit Now.
Time left > 0029
Please Exit Now.
Time left > 0029
Please Exit Now.
Time left > 0029
SYTEM OPEN
08:30 Sun 28 Apr

View Location Text

This option allows the engineer to view the panel
location text. The text message is programmed in
"Engineers menu 2", see page 41.
LCD Only
Engineers menu 1
Select Options :-
PANEL IS IN
RECEPTION CLOSET
View Location Text Flowchart

Relearn Hardware

If the system hardware configuration has
changed whilst in engineers mode, for example a
remote keypad added or removed from the
system. The system will show "RELEARN REQUIRED"
when exiting from engineers mode. To clear this
message you must re-select engineers menu 1
and press [C], the panel will generate an
acceptance tone and all current hardware is
re-logged on to the system. It is advisable that you
confirm the new hardware by viewing the system
log, see page 38.
Relearn Hardware Flowchart
TS590 Installation Manual
B
ESC
LCD
Engineers menu 1
Select Options :-
C
Re-map Devices
Enter Device >--
Enter ID device No (01 - 30)
e.g. 18
ENT
Re-map Devices
to Circuit >18
The display shows the
current mapping.
Enter new circuit No.
e.g. 21
Re-map Devices
to Circuit >21
ENT
[1.B]
Location Text
[1.C]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents