Datamax M-Class Mark II Maintenance Manual page 56

Printers
Hide thumbs Also See for M-Class Mark II:
Table of Contents

Advertisement

Displayed Message
CUTTER FAULT
DMA FAULT
GAP MODE
CANNOT CALIBRATE
Troubleshooting
Fault Messages (continued)
Description
Blade positioning has
failed.
Direct Memory Access
has failed.
Consistently low sensor
readings have occurred.
3-14
Possible Solution(s)
Cycle power OFF and ON. Then,
ensure that media thickness is
within specification for the cutter.
Retry. If the fault continues, try the
following:
WARNING! Turn OFF and
unplug the printer before
proceeding.
1) Ensure that the cutter is properly
installed and that the cable is
connected and undamaged.
2) Clean the cutter and ensure that
the mechanism is unobstructed.
3) The cutter may be defective;
replace it.
4) The Main Logic PCB may be
defective; see Section 4.4.
Cycle power OFF and ON. If the
fault does not clear, replace the
Main Logic PCB; see Section 4.4.
Press any key to continue then try
the following:
1) Retry calibration, ensuring that
media was inserted in the sensor
during the appropriate step.
2) Clean the sensor (see Section
2.1.2) then retry calibration.
3) Try Advanced Entry Calibration;
see Section 2.2.2.3.