TS690 & TS690ID Installation Manual

Go to User Menu 1

This option allows the engineer to access "User
menu 1", the flowchart below shows the options
within "User menu 1", for full details refer to the
"Operators Manual".
Engineers menu 1
Select Option :-
0
User menu 1
Select Option :-
1
Bell Test
2
Walk Test
Remote
3
Reset
Change
4
code
Enable
5
Chime
Omit Shunt
6
Group
Omit
7
Circuits
8
Silent Set
0
Full Set
A
Part Set A
B
Part Set B
C
Part Set C
ESC
User Menu 1 Flowchart
[1.0]
ESC
Sounder. ON > 08
Press ESC to end
Walk Test
Press ESC to end
Remote Reset
Quote > 6846
Change passcode
New code > ----
Chime ccts are
Enabled
CCTS ISOLATED
08:30 Sun 28 Apr
Omit Circuits
Enter CCT No.>--
Silent Set ?
Enter Group > -
Please Exit Now.
Time left > 029
Please Exit Now.
Time left > 0029
Please Exit Now.
Time left > 0029
Please Exit Now.
Time left > 0029
SYTEM OPEN
08:30 Sun 28 Apr

Add/Clear ID Devices (TS690ID)

This option allows the engineer to add and remove
ID devices from the system. It also allows you to
diagnose the ID loop.
Clear & Relearn ID Devices
This option causes the system to clear any
previously learnt devices and re-scan the ID loop
and learn all connected devices. In order for a
device to be detected the device must NOT be in
a tamper condition.

Add ID Devices

This option causes the system to re-scan the ID
loop and only learn new devices that have been
connected. In order for a new device to be
detected the device must NOT be in a tamper
condition.

Display Codes

When using the "Clear/Add ID Devices" option the
top line of the display shows that status of ID
devices 1 to 15, the bottom line of the display
shows the status of ID devices 16 to 30. The
following characters are used to indicate the
following status:
.
Device not fitted.
H
Device is healthy (normal)
A
Device is active (alarm).
T
Device is in tamper.
Device is in a fault condition (normally caused by
F
two devices fitted with the same ID).

Slow Scan Mode

The "SLOW SCAN" mode can be used to diagnose
the ID line and check for correct voltage levels at
each ID device. When selected the ID loop
continuously cycles through the RESET, MID and
HIGH conditions (5 seconds for each). For correct
operation, the voltages should be:
RESET
1.9V to 2.4V
MID
5.6 to 6.4V
HIGH
9.0 to 10.1V