Engineer's Menu 1

Panel Outputs

Outputs 1-3 on the control panel and remote
keypad outputs 5-8 can be programmed to any
of the output types shown on pages 26 to 28.
LCD
Engineers menu 1
Select Options :-
Panel Output ?
Enter Number > -
Enter output No. 1 - 8
e.g. 1
Panel Output 1
is type > 004
Type No.
Enter new output type
e.g. 021
Panel Output 1
is type > 021
Panel Outputs Flowchart

Digicom Outputs

The 5 digicom outputs on the control panel PCB
can be programmed to any of the output types
shown on pages 26 to 28. In addition, all outputs
can be inverted, see "Configuration option 19" on
page 35.
Engineers menu 1
Select Options :-
Digi Output ?
Enter Number > -
Enter output No. 1 - 5
e.g. 5
Digi Output 5
is type > 013
Type No.
Enter new output type
e.g. 043
Digi Output 5
is type > 043
Digi Outputs Flowchart
26
Starburst
ENGR 1 -
1
PANEL -
004
021
ENT
LCD
Starburst
ENGR 1 -
2
DIGI OP -
013
043
ENT
[1.1]

Digicom Channels

The 8 plug-on digicom channels can be
programmed to any of the output types shown on
pages 26 to 28.
LED
E1 -
PAN. -
004
Type No.
021

Programmable Output Types

[1.2]
No
Type/Description
000 Bell On
Activates when the main Bell trigger is on and
deactivates at the end of the Bell Duration
time or when the alarm is cancelled by the
LED
user.
001 Strobe On
E1 -
Activates when the Strobe trigger is on, and
deactivates when the alarm is cancelled by
the user.
DIG. -
002 Switch 12V
Activates when the system is set and
deactivates when an alarm occurs or the
system is unset. This output is normally used for
013
latching detectors.
003 Detector Reset
Normally active at all times and deactivates
for 3 seconds when a valid passcode is
entered prior to setting the system. This output
043
is normally used for detector that required
power to be removed in order to reset them,
e.g., smoke detectors.
TS690 & TS690ID Installation Manual
LCD
Engineers menu 1
Select Options :-
3
Digi Channel ?
Enter Number > -
Enter channel No. 1 - 8
e.g. 8
Digi Channel 8
is type > 011
Enter new output type
e.g. 055
Digi Channel 8
is type > 055
ENT
Digi Channels Flowchart
[1.3]
Starburst
LED
ENGR 1 -
E1 -
DIGI CH -
Dc5. -
011
011
055
055