No
Type/Description
004 Walk Test
Activates when the "Walk Test" option is
selected and deactivates when the "Walk Test"
option is finished.
005 Alarm
Activates when an intruder alarm is detected
and deactivates when the alarm is reset or
aborted.
006 P.A.
Activates when a PA alarm is detected and
deactivates when the alarm is reset.
007 Fire
Activates when a Fire alarm is detected and
deactivates when the alarm is reset.
008 System Set
A c t i va t e s w h en an y w a rd is set an d
deactivates when the system is fully unset.
009 Code Accepted
Activates for 5 seconds following entry of any
valid passcode.
010 24 Hour
Activates when a 24Hr alarm is detected and
deactivates when the alarm is reset.
011 Second Alarm
Activates when a different detector causes an
alarm and remains active for the duration of
the "2nd Alarm Time". This output is normally
used as an ALARM CONFIRMATION signal.
012 Courtesy Light
Activates during entry and when any remote
keypad is used. The duration of this output is
controlled by the setting of the "COURTESY
DUR" timer.
013 Engineer On Site
Activates when the engineer's passcode is
entered and deactivates when a user
passcode is entered.
014 Circuits Omitted
Activates when any circuit is omitted and
deactivates when all circuits are reinstated.
015 Auxiliary
Activates when an Auxiliary alarm is detected
and deactivates when the alarm is reset.
016 Part Set C Selected
Activates when "Part Set C" is selected.
Deactivates when the system is unset.
No
Type/Description
017 Part Set B Selected
Activates when "Part Set B" is selected.
Deactivates when the system is unset.
018 Part Set A Selected
Activates when "Part Set A" is selected.
Deactivates when the system is unset.
019 Full Set Selected
Activates when "Full Set" is selected.
Deactivates when the system is unset.
020 Tamper Fault
Activates when a Tamper alarm is detected
and deactivates when the alarm is reset.
021 Line Fault
Activates when a telephone line fault is
detected and deactivates when the fault is
cleared.
022 Mains Off
Activates when mains power is removed and
deactivates when the mains power is restored.
023 Exit / Entry
Activates when the panel is in the exit or entry
mode.
024 Test Fail
Activates when a circuit fails test, deactivates
when reset by the engineer.
025 First Knock
Activates when a double knock circuit is
activated for the first time. Deactivates when
the circuit is activated for the second time or
when the system is reset.
026 Comms Failed
Activates for 5 seconds when the plug-on
digicom fails to communicate.
027 Comms Success
Activates for 5 seconds when the plug-on
digicom communicates successfully.
028 Comms Active
Activates when the plug-on digicom is active
and deactivates when the plug-on digicom is
inactive.
029 2nd Entry
Activates when the second entry timer is
started and deactivates when the second
entry timer expires.
030 Entry
Activates when the panel is in the entry mode.
031 Exit
Activates when the panel is in the exit mode.