TS690 & TS690ID Installation Manual
4. Connect "Remote Network" cables and
detection circuit cables to the appropriate
terminals, see Figure 10
5. Set the I/D selector jumper link to the required
position:
I/D Selector
Circuit A
1
07
2
09
3
11
4
13
ENG/NULL
N/A
I/D Selector
Circuit A
1
31
2
33
3
35
4
36
ENG/NULL
N/A
No two LECs or remote keypads should
l
have the same I/D.
DO NOT set the I/D selector to the "NULL"
l
position.
6. Finally clip the LEC cover onto the base being
careful not to trap any cables or to obstruct the
tamper switch.

Wiring Detection Circuits

All detection circuits may be wired as "End Of Line"
(EOL) or "Double Pole" (DP). Both methods can be
used on the same equipment.

Double Pole

The DP method requires the following:
The detector alarm and tamper contacts are
l
connected to the zone and tamper terminals
respectively.
The combined alarm and tamper loop
l
resistance must be less than 100 Ohms.
The maximum number of detection devices
l
allowed in a circuit is ten.
TS690
Panel
Circuit B
Output
08
5
10
6
12
7
14
8
N/A
N/A
TS690ID
Panel
Circuit B
Output
32
5
34
6
36
7
38
8
N/A
N/A
Normally open devices such as pressure pads
l
and exit terminator buttons are connected
between the zone and tamper terminals.
If the detection circuit is not used links can be
l
fitted across the zone and tamper loops or
programmed as Not Used.
Alarm
Tamper
Max. 10 devices per circuit
Wiring N.O. devices (Exit Terminators)
Figure 12. Double Pole Wiring

End Of Line

The EOL method requires the following:
The detector alarm contacts must have a 4K7
l
shunt resistor fitted.
A 2K2 End of Line (EOL) resistor must be fitted at
l
the point in the circuit furthest from the control
panel.
Loop resistance with the EOL resistor shorted
l
must be less than 100 Ohms.
The maximum number of detection devices
l
allowed in a circuit is ten.
Normally open devices such as pressure pads
l
and exit terminator buttons are connected
across outer terminals
If the detection circuit is not used links can be
l
fitted across the zone and tamper loops or
programmed as Not Used.
System Installation
500 metres or 100 Ohms