Log Event Codes; Reset User Code 1; Start Call Back - Menvier Security TS690 Installation & Programming Manual

Intruder alarm control panels
Table of Contents

Advertisement

Engineer's Menu 2

Log Event Codes

LCD
PANEL LID TAMPER
PART SET A/B/C
PASSCODE 00-15
RELEARN REQUIRED
REM REMOVED 01-04
REM SERVICE CALL
REM TAMPER 01-04
REMOTE ADDED 01-04
REMOTE RESET
SERVICE CALL END
SERVICE REQUIRED
SET FAIL
SYSTEM OPEN
SYSTEM RE-ARMED
SYSTEM SET
TAMPER 00
TAMPER 01-38
TEST CCTS OFF
TEST FAIL 01-38
TIME CHANGED

Reset User Code 1

This option allows the installation engineer to reset
the master user (user 01) back to the factory
default code of "5678". This feature is useful when
the master user has forgotten their passcode or
has accidentally changed it without realising. This
operation is logged.
LCD
Engineers menu 2
Select Option :-
Press ENT to
Reset User 1 ?
to reset user 1
Reset User Code Flowchart
44
Starburst
LID TAMP
P.SET A/B/C
USER 00-15
RESET CONFIG.
R. REM 01-04
R.S. CALL
R. TMP 01-04
R. ADD 01-04
REM RST
R.S. END
SERVICE
SET FAIL
SYS OPEN
RE-ARMED
FULL SET
TAMP'R 00
TAMP'R 01-38
TEST OFF
T. FAIL 01-38
TIME CHG
Starburst
ENGR 2 -
0
RESET
USER 1 ?
ENT
LED
LT
Control panel lid removed.
PS. A /B/C
System Part-Set using one of the A, B, or C buttons.
Ur. 0 0-15
User passcode entered. (00-15).
REST CON.
Hardware relearn required see page 38.
rr. 0 1-04
Remote Keypad removed from system.
SC
Remote service call via "Lineload" software and PC.
rT. 0 1-04
Remote Keypad cover removed.
RA. 0 1-04
Remote Keypad added to the system.
rc
System reset by "Remote Reset" passcode.
SE
Remote service call finished.
rS
Service required
SF
System failed to Set.
OP
System fully unset.
rA
System re-armed all healthy circuits.
FS
System fully set.
TA. 0 0
Short circuit on ID loop.
TA. 0 1-38
Tamper alarm from circuit.
To
All circuits taken off "Test"
TF. 0 1-38
Circuit failed during "Test".
Tc
System time changed
[2.0]

Start Call Back

If the system is fitted with a digi-modem, it is
possible for the installation engineer to initiate an
upload sequence to a remote site (normally the
alarm company). Once the communication link is
established with the remote site, data can be sent
and received from the control panel. This feature is
only compatible with Menvier Lineload software
version 2.5 or above.
LED
E2 -
REST
USR 1
TS690 & TS690ID Installation Manual
Description
[2.A]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts690id

Table of Contents