Connecting a Printer

The TS690 and TS690ID supports two type of
printers, the CPA6 printer (no longer available) and
any standard RS232 printer. When using an RS232
printer a DCI/MPA printer adaptor will be required.
Menvier Security supply a DATAC printer kit which
consists of a portable RS232 printer, charger unit
and DCI adapter.
Connect to JP1
PRINTER
MPA
or DCI
RS232 Data
Connect to JP1
PRINTER
Figure 24. Printer Connections

Using the DATAC / RS232 Printer

1. Plug the DCI/MPA on to the PRINTER plug (JP1)
on the main control panel PCB.
2. Plug the other end of the DCI/MPA into the
DATAC or RS232 printer.
3. In order for the printer to work correctly ensure
that the printer is set to the following:
Baud rate
= 4800
Parity
= None
Start bits
= 1
Stop bits
= 2
Data bits
= 8
DTR
= Normal
4. When setup correctly the system program
details and event log can be printed.
5. When finished unplug the MPA/DCI. If the
printer is left connected events will be printed
as and when they occur.
CPA6 Printer
DATAC or RS232 printer

Using the CPA6 Printer

6. Plug the CPA6 printer directly on to the PRINTER
plug (JP1) on the main control panel PCB.
7. The printer will printout a header, when finished
the system program details and event log can
be printed.
8. When finished unplug the printer. If the printer is
left connected events will be printed as and
when they occur.

Programmable Outputs

The TS690 and TS690ID has many programmable
outputs which can be used to drive relays, LED's
etc. Each output can be programmed for a
different function, see "Programmable Output
Types" on page 26.

Control Panel Outputs

The control panel has three programmable
outputs:
[1]
Set of voltage free changeover contacts
rated at 1 Amp.
[-2]
Switched -ve output rated at 500mA.
[+3]
Switched +ve output rated at 500mA.
Remote Keypads & TS700.LECs
Each remote keypad and TS700 LEC has one
programmable output:
[O/P]
Switched -ve output rated at 100mA.