Programming; Engineer Menu 1; Panel Outputs; Digicom Outputs - Menvier Security TS700 Installation & Programming Instructions

Intruder alarm control panel
Table of Contents

Advertisement

Programming

Programming

Engineer Menu 1

Engineers menu 1 is selected when the engineer's passcode is entered during the unset condition.
The engineer may leave engineer menu 1 by pressing the [ESC] key. The system will return to the
unset condition but the remote keypads will show: "ENG ON SITE". This message will be cleared the
next time a valid user passcode is entered. When engineers mode is selected the monitoring of
tamper circuits is disabled.

Panel Outputs

Outputs 1 to 4 for the control panel and 5 to 8 for the remote keypads can be programmed to any
of the output function types 0 to 55 as listed in Table 2 on page 15.
1.
Ensure that "Engineer Menu 1" is selected.
2.
Press 1 to select the Panel Outputs option.
3.
The display will show: PAN. -
4.
Enter the required output number 1 to 8.
5.
The display will show the current output function (Table 2).
6.
Enter the new function number and press [.
7.
The display will return to step 3. Repeat steps 4 to 7 for the
remaining outputs.
8.
Press ] to return to "Engineer Menu 1".

Digicom Outputs

The eight switched -ve Digicom outputs 1 to 8 may be connected to the Digicom channel inputs.
The outputs may be programmed to any of the function types 0 to 55 (Table 2).
1.
Ensure that "Engineer Menu 1" is selected.
2.
Press 2 to select the Digicom Outputs option.
3.
The display will show: DIG. -
4.
Enter the required digicom output number 1 to 8.
5.
The display will show the current output function (Table 2).
6.
Enter the new function number and press [.
7.
The display will return to step 3. Repeat steps 4 to 7 for the
remaining digicom outputs.
8.
Press ] to return to "Engineer Menu 1".

Plug-on Digicom Channels

The eight channels for the plug-on digicom may be programmed to any of the function types 00
to 55 (Table 2). The procedure is similar to programming the digicom outputs (above).
1.
Follow above procedure, except press 3 at step 2.
16
TS700 Installation Manual
PAN. -
Enter panel output 1 - 4 or
remote output 5 - 6.
04
Enter new output type 00 - 55
(see Table 2.)
DIG. -
Enter digicom output 1 - 8.
04
Enter new output type 00 - 55
(see Table 2.)
Dc3. -
Enter digicom output 1 - 8.

Hide quick links: