On-Board Diagnostics
BMW
P-code
code
110
P1542
111
P1542
112
P0120
MS 42
MS 43
113
P0120
114
P1580
MS 42
MS 43
115
P1623
MS 42
MS 43
116
P1623
8 of 20
Fault type and
Signal type and
function
range
Pedal sensor
Input analog
potentiometer 1
(0-5V)
Pedal Sensor
Input analog
Potentiometer 2
(0-5V)
Motor throttle valve
Input analog
potentiometer 1
(0-5V)
Throttle position
Input analog
sensor 1
(0-5V)
Motor throttle valve
Input analog
potentiometer 2
(0-5V)
Motor throttle valve
DME internal test
final stage
A second pedal
DME internal
sensor range
values logical
check failure is
determined
Output voltage 5V
DME internal (5V)
for potentiometer
operation 1
Range check for
Input analog
throttle position
(0-5V)
adaptation
Output voltage for
DME internal (5V)
potentiometer
operation 2
http://ebahn.bentleypublishers.com/BMW/3/E46/Repair%20Manuals/8...
Explanation
spring within motor throttle
body.
Failed signal range check
against predefined diagnostic
limits.
Failed signal range check
against predefined diagnostic
limits.
Failed signal range check
against predefined diagnostic
limits.
Failed signal range check
against predefined diagnostic
limits.
Failed signal range check
against predefined diagnostic
limits.
Final stage inside DME
(special H-bridge), will set
internal flag whenever a short
to ground, a short to battery
voltage or a disconnection
occurs.
If pedal sensor malfunction is
determined, followed by a
second malfunction, a signal
is sent.
Check for proper 5 volts
supply to potentiometers is
possible within a predefined
voltage limit.
Range check for closed
position of throttle sensors.
Check for proper 5 volts
supply to potentiometers is
possible within a predefined
voltage limit.