102
Chapter 5: Programming commands
m
Bar code
70
Interleaved 2 of 5 (ITF)
30-39
71
CODABAR (NW-7)
72
Code 93
73
Code 128
74
Code 128 auto compress
75
PDF 417
78
Code EAN 128 auto compress 0-255
79
PDF 417
data length specified via
integer n = nH:nL
1D 6B m nL nH d1 . . . dn
The value of m selects the bar code system as described in the table. The variable d indicates the character code to
be encoded into the specified bar code system. If character code d cannot be encoded, the printer prints the bar code
data processed so far, and the following data is treated as normal data.
Exceptions
Illegal data cancels this command.
PDF 417 format cannot be printed on the slip.

Set GS1 DataBar (formerly RSS) parameters

Setting of parameters for GS1 Databar.
ASCII
GS q a b c d e fL fH
Hexadecimal
1D 71 a b c d e fL fH
Decimal
29 113 a b c d e fL fH
a
byte
b
byte
c
byte
d
byte
e
byte
f
word
Note: For GS1 DataBar commands, consult ISO/IEC 24724. For further information, visit www.gs1.org.
A776 (B780) Programming Guide
d1...dn
48–57
65–68, start code 48–57, 36, 43, 45, 46, 47, 58
41-44, start code 30-39, 24, 2B, 2D, 2E, 2F, 3A
00–127
00-7F
0–105 d1 = 103–105 (must be a start code)
d2 = 0–102 (data bytes) (Stop code is provided by the printer)
0-255
00-FF
0–255
00-FF
00-FF
0-255
00-FF
pixels per minimum unit, default 3, minimum 2, maximum 6 (value a applies
to parameters b, c, d)
X undercut, default 0, can be set 0 to a-1
Y undercut, default 0, can be set 0 to a-1
separator height, default a, can be set a to a*2
segment width, used only by GS1 DataBar Expanded, default 22, must be
even number 2 to 22
line height, used only by UCC128, default 25, can be set 1 to 500
n
Variable (even number)
Variable
Variable
Variable
Variable
Variable
Variable
Variable
0 < n < 2800