86
Chapter 4: Programming Commands
·
Parameters for alignment, height, width, and HRI can be set before or after 1D 6B FF 01 command
·
No height restriction change from single line barcodes
·
Quiet zone between barcodes = 10 * module width
·
No text in between barcodes (results undefined)
·
Upright, picket fence barcodes only, no upside down or ladder. Extended barcode printing for upside down and
ladder barcodes can be done in page mode if required.
·
Slip/validation selection disabled in multiple barcodes command string
·
Multiple barcodes command string disabled when slip/validation selected
·
Page mode disabled in multiple barcodes command string
·
Multiple barcodes command string disabled in page mode
·
Page mode parameters initialized at end of multiple barcodes command string
Sample multiple barcodes command string:
1b 40
1d 6b ff 01
1b 61 01
1d 68 40
1d 77 02
1d 48 02
1d 6b 49 06 67 27 2d 2e 2d 2e

Set GS1 DataBar (formerly RSS) parameters

ASCII
GS q a b c d e fL fH
Hexadecimal
1D 71 a b c d e fL fH
Decimal
29 113 a b c d e fL fH
a
byte
b
byte
c
byte
d
byte
e
byte
f
word
Note: For GS1 DataBar commands, consult ISO/IEC 24721. For futher information, visit www.gs1.org.
Initialize
Begin multiple barcodes one line
Center align
Barcode height
Barcode width
Print HRI below
Barcode 1, code 128
pixels per minimum unit, default 3, minimum 2, maximum 6 (value a applies
to parameters b, c, d)
X undercut, default 0, can be set 0 to a-1
Y undercut, default 0, can be set 0 to a-1
separator height, default a, can be set a to a*2
segment width, used only by GS1 Expanded, default 22, must be even
number 2 to 22
line height, used only by UCC128, default 25, can be set 1 to 500
A798-PG00001C