Set Gs1 Databar (Formerly Rss) Parameters; Select Pdf 417 Parameters - CognitiveTPG A799 Programming Manual

A799 two-color thermal receipt printer
Hide thumbs Also See for A799:
Table of Contents

Advertisement

Revision D 12/09

Set GS1 DataBar (formerly RSS) parameters

Setting of parameters for GS! DataBar
ASCII
GS q a b c d e fL fH
Hexadecimal
1D 71 a b c d e fL fH
Decimal
29 113 a b c d e fL fH
a
byte
b
byte
c
byte
d
byte
e
byte
f
word
Note: For GS1 DataBar commands, consult ISO/IEC 24721. For further information, visit www.gs1.org.

Select PDF 417 parameters

ASCII
GS p a b c d e f
Hexadecimal
1D 70 a b c d e f
Decimal
29 112 a b c d e f
Value and Ranges:
Value:
Ranges:
a, b =
a = height
limit 1 to 10
b = width
limit 1 to 100
c =
rows
limit 3 to 90
d =
columns
limit 7 to 30
e =
x dimension
limit 1 to 7
f =
y dimension
limit 2 to 25
Defaults:
a = 1
b = 2
c = 58
d = 7
e = 3
f = 10
PDF 417 is a multi-row, continuous, variable length symbology which has high data capacity. Each symbol has between 3
and 90 rows, with each row containing a start pattern, a left row indicator, 1 to 30 data characters, a right row indicator and
a stop pattern. The number and length of the rows are selectable, which allows the aspect ratio to be adjusted to particular
labeling applications. There are no separator bars between rows.
Each character has four bars and four spaces within 17 modules, and is assigned a value between 0 and 928. For this
symbology, it is common to refer to these character values as "code words."
There are three mutually exclusive sets of symbol patterns, or clusters, each having 929 distinct patterns. Because different
clusters are used for adjacent rows, it is possible for the decoder to tell if the scanning path is crossing row boundaries
without the use of separator bars.
pixels per minimum unit, default 3, minimum 2, maximum 6 (value a applies
to parameters b, c, d)
X undercut, default 0, can be set 0 to a-1
Y undercut, default 0, can be set 0 to a-1
separator height, default a, can be set a to a*2
segment width, used only by GS1 DataBar Expanded, default 22, must be
even number 2 to 22
line height, used only by UCC128, default 25, can be set 1 to 500
Description:
The ratio of bar height to symbol length.
Number of rows in the matrix of code words.
Number of columns in the matrix of code words.
Width of a single module in dots.
Height of the code word in dots.
A799-PG00001D
Chapter 4: Programming Commands
103