Chapter 5: Programming commands
Decimal Value
Definition
297
Reserved for FW Page Number & Number of Pages p1= bottom scanner, p2= top scanner; these
are saved as type = two short integers
305
Application supplied string: Software = version description
306
FW supplied Date & 24 Hour Time of scan: 20 char YYYY:MM:DD:HH:MM:SS; must be application
initialized to start FW time stamping
33432
Application supplied string: Copyright
65000
Reserved for FW auto generated int FileIndex value
65001
Reserved for FW auto saved int of set transmission format parameter (m p r) values
65002
Reserved for FW auto saved raw MICR read string, if MICR present
65003
Reserved for FW auto saved int of entry point: 1 = slip, 2 = front
65004
Reserved for future FW auto saved reporting
65005
Reserved for FW auto save of parsed MICR string (if parsing has been defined)
65007-534
Any other Application set descriptions, usually strings, but any TIFF type
A few tag values that are useful to TIFF readers always have the default values and thus are not repeated in the
returned structure. These are 266, Fill Order = 1; 274, Orientation = 1 (top left is 0,0); and 277, Samples Per Pixel = 1.

Attach Scan Application Tags

Hexadecimal: 1D B6
Parameters: None
Return: 1D 49 B6 m. M is 0 if OK, 1 if the scanned image already has application set tags or there is no last scanned
image.
Description: Attach the current set of application defined tags to the last scanned image. This can be done only once
to each image and allows the application to define tags up to image file transmission time. Note that this action takes
place automatically in the case of the scan command with its parameter set for immediate transmission.

Return Imager Status

Hexadecimal: 1D B7
Parameters: None
Return: 1D 49 B7 s m n pL pH rL rH
Value
Definition
1D
Command return indicator
49
Image Scanner
B7
Imaging function = status
s
Standard imaging status
Decimal
0
1
2
3
7
Continued . . .
A776 (B780) Programming Guide
Meaning
OK
Jam detected
Wait for scan document cancelled
Imager cover open
Unrecoverable hardware error