14
Chapter 3: Migrating to a new printer

A776 Configurable Slip Commands

A776 Double High Slip Character Print

Code (Hexadecimal)
1F 03 26 01 n
Double high slip character print command (1B 21 10)
n
00
Disabled
01
Enabled

A776 Slip Character Spacing

Code (Hexadecimal)
1F 03 26 02 n
Slip character right side spacing command (1B 20 n)
n
00
Disabled
01
Enabled

A776 Slip Minimum Units

Code (Hexadecimal)
1F 03 26 03 n
n
Set minimum units for the slip station command (1D 50 x y)
00
Disabled
01
Enabled

A776 Slip Left Margin and Print Width

Code (Hexadecimal)
1F 03 26 04 n
n
Set left margin(1D 4C nL nH) and print width(1D 57 nL nH) on the slip station commands
00
Disabled
01
Enabled

A776 Slip Print Justification

Code (Hexadecimal)
1F 03 26 05 n
Print justification on the slip station command(1B 61 n)
n
00
Disabled
01
Enabled
A776 (B780) Programming Guide
Command
1B 21 10 command
Enables or disables the
Command
1B 20 n command
Enables or disables the
Command
1D 50 x y command
Enables or disables the
Command
Enables or disables the 1D 4C nL nH and 1D 57 nL nH commands
Command
1B 61 n command
Enables or disables the
A776-PG00001 C 12/09