Interactions with other software releases
OmniPCX Office release 5.1 requires 4 kinds of DECT initialization: Europe, Latin America,
United-States and China. See also:
4.9.1.6
LIMITS
Number of IBSs: 20 IBSs per cabinet is recommended, however, the number of IBSs is only
restricted by the available power.
DECT link limit: 3 links on an IBS with one UA access, 6 links on an IBS with 2 UA accesses.
DECT handset limit: up to 120 handsets on a system.
4.9.1.7
PERFORMANCE AND QUALITY
IBSs are downloaded during the system start phase or when hot plugged. A system with many
IBSs plugged might take longer to complete the start phase.
Downloading 1 IBS takes about 30 seconds. It takes more time when several IBSs are
plugged on the same UA resource.
The end of restart is only possible after all the devices have been taken into account.
If an IBS downloading fails, the IBS restarts with the previously installed software.
4.9.1.8
IBS CONFIGURATION
There is no hardware configuration for IBS other than selecting between an external power
supply for each IBS and remote power by system.
To configure the IBS software:
ARI Number
The ARI number identifies each OmniPCX Office. Each OmniPCX Office has an identical
default ARI number.
When you install a new OmniPCX Office, you have to change the default ARI number. You
can only keep the first digit, which is "1" and which means "ARI type B".
-
1 In OMC, go to System Miscellaneous -->DECT/PWT ARI/GAP
-
2 Enter your own number (octal digit) to register your DECT handset.