CHAPTER 10 Expansion File Unit Type-2

10.3 Preparations for Use

This section describes the following:
 Installation notes
 Installation specifications
10.3.1 Installation notes
CAUTION
Rack installation notes
180
Unit Damage
If the following notes are not observed the Expansion File Unit Type-2 may be
damaged. Be sure to follow these notes.
The following installation instructions are intended to provide product safety requirements to be
addressed when the end-use product manufacturer installs this product in their equipment.
 As the Expansion File Unit Type-2 is installed in a closed or multi-unit rack assembly, the
operating ambient temperature inside of the rack environment may be greater than the room
temperature. So, consideration should be given to installing the Expansion File Unit Type-2 in
an environment compatible with the manufacturer's maximum rated ambient temperature.
– Consideration for adjustment of air conditions like air circulation should be given to
prevent the internal rack ambient temperature from exceeding the maximum operating
temperature of this unit.
– Maximum internal operating temperature of this unit: 35 deg. C (95 deg. F)
 Installation of the Expansion File Unit Type-2 should be such that the amount of air flow
required for safe operation of the Expansion File Unit Type-2 is not compromised.
– The Expansion File Unit Type-2 has ventilation openings at the front and rear faces of the
unit.
– To prevent overheating, do not cover or close these ventilation openings.
 Mounting of the Expansion File Unit Type-2 in the rack should be such that a hazardous
condition does not result from uneven mechanical loading. To maintain the stability of the
entire rack, please fix the rack to the wall or floor by suitable means.
– Be careful of injuries during installation of the Expansion File Unit Type-2 into the rack.
– Do not install the Expansion File Unit Type-2 into a rack if the server unit may make the
entire rack unstable.
– Maximum configured weight of this unit: 30 kg (66.14 lb.)
 If the Expansion File Unit Type-2 is supplied with power from a power strip or service outlet of
other units, it may overload the power supply cord or the power strip of other units.