 To prevent condensation in the PRIMEPOWER600 Pedestal Server, do not raise the ambient room
temperature rapidly in winter.
Use the PRIMEPOWER600 Pedestal Server only after it has warmed up sufficiently.
 Do not install the PRIMEPOWER600 Pedestal Server near EM noise generating devices such as
photocopiers, air conditioners, or welders.
 Take electrostatic prevention measures. Note that some carpets generate static electricity easily and can cause
the PRIMEPOWER600 Pedestal Server to malfunction.
 When moving the PRIMEPOWER600 Pedestal Server, do not pull on the front cover. Otherwise, the Server
may be damaged.
Connect the ground before connecting any of the power supply lines. If all of the
CAUTION
power cables are connected to a single power strip, high leakage current
exceeding the stipulated value may leak through to the earth lead of the power
strip.
If the power strip is not directly connected to the main distribution panel, use a
power strip with an industrial plug.