LED / Button Name
2.6 LED
6.0 LED
10.0/15.0 LED
20.0 LED
35.0 LED
Compress LED
Density Override
LED
Select Button
Write Protect LED
Tape in Use LED
Use Cleaning Tape
LED
Operate Handle
LED
Unload Button
All 7 Left-hand
LEDs or
All 4 Right-hand
LEDs
(Example)
When the loaded tape has previously been recorded at 20.0GB, if the Select Button is used to set the recording
density to 35.5 GB, and new data is recorded on the tape, then the Indicator LEDs will change as follows:
Before recording:
After recording:

11.6.2 SCSI ID

Set the SCSI ID of the DLT tape drive to "5".
State (Color)
(Dark)
(Not currently used)
Lit (Amber)
Record density of the loaded tape.
Blinking (Amber)
Recording density to be used to write data
(if different from the current format).
Lit (Amber)
Compression mode is active.
Dark
Compression mode is inactive
(data will be written non-compressed).
Lit (Amber)
Data will be written using the recording
density specified by the Select Button.
Blinking (Amber)
Select Button is being used to set the
recording density.
Dark
Data will be written using the recording
density specified by the host software.
---
Use to manually set the compression
mode (compressed/non-compressed)
and recording density (20.0/35.0).
Lit (Orange)
Loaded tape is set to "read only".
Dark
Loaded tape may be written to.
Lit (Amber)
Tape is loaded (and idle) in the drive unit.
Blinking (Amber)
Tape is moving or drive unit is performing
diagnostics.
Dark
No tape is currently loaded.
Lit (Amber)
Tape heads require cleaning.
Lit (Green)
Cartridge handle can be used to eject the
loaded tape.
Dark
Cartridge handle cannot be currently
operated.
---
Pressing readies the loaded tape for
ejection.
Lit
POST diagnostics are running.
Blinking
Fault detected.
20.0 LED = Lit
20.0 LED = Dark
Description
35.5 LED = Blinking
35.5 LED = Lit
11.6 DLT Tape Drive
Note
(See example below)
Set using the Select Button.
(See example below)
Set using the Select Button.
Set using the Select Button.
If lit, the settings of the host
software will be ignored.
For details, see ⁄9.6.9
"Cleaning the tape heads".
For details, see ⁄9.6.8
"Ejecting a data cartridge".
If reboot does not clear
fault, contact a CE for help.
Density Override LED = Lit
Density Override LED = Lit