Power supply unit, fans, environmental monitoring
The messages shown in Table 13.3 are displayed if an error is detected in the power supply units,
fans or temperature while the system is running.
Table 13.3
Message
(1st line)
SCF:warning
SCF:alarm
Processor monitoring error messages
The messages shown in Table 13.4 are displayed if an error is detected by the CPU monitor during
POST diagnostics or while the system is running.
Message
(1st line)
SCF:alarm
Power Supply Unit, Fans, and Environmental Error Messages
Message
(2nd line)
FAN x-y
FAN x-y (m-n)
FEP#x
FEP#x (#y)
FAN x-y
FAN x-y (m-n)
Thermal Inlet
Thermal CPU
Sensor Inlet
FEP#x
FEP#x (#y)
0x-DDC#y
PPU3#x
PPU5#x
PPU12#x
FEP DC-ON 0x
0x-DDC DC-ON xx
PPU2 DC-ON 0x
PPU3 DC-ON 0x
PPU5 DC-ON 0x
PPU12 DC-ON 0x
Table 13.4
CPU Monitor Error Massages
Message
(2nd line)
CPU Hangup xx
CPU Hangup 00xx
Cause
Error detected at fan #y of fan tray #x.
(m-n): Multiple events detected.
Abnormality detected at FEP #x.
(#y): Multiple events detected.
Fault detected at fan #y of fan tray #x.
(m-n): Multiple events detected.
Abnormal ambient temperature detected
(exceeding approx. 40ßC / 104ßF).
Abnormal CPU temperature detected.
Abnormal temperature sensor detected.
Abnormality detected at FEP #x.
(#y): Multiple events detected.
Abnormality detected at DDC #x.
Abnormality detected at 3.3V PPU #x.
Abnormality detected at 5V PPU #x.
Abnormality detected at 12.0V PPU #x.
Failed to power-on FEP #x.
Failed to power-on DDC #xx.
Failed to power-on 2.5V PPU #x.
Failed to power-on 3.3V PPU #x.
Failed to power-on 5.0V PPU #x.
Failed to power-on 12.0V PPU #x.
Cause
Processor hang-up detected in power-on
processing phase xx.
Processor hang-up detected in system
operating environment xx.