JUNOS Software with Enhanced Services Hardware Guide
Table 8: J2320 and J2350 ALARM LED (continued)
Color
Yellow
Unlit
For information about alarm conditions and corrective actions, see "Monitoring and
Correcting Chassis Alarm Conditions" on page 157. For additional information, see
the JUNOS Software Administration Guide.
HA LED
The HA (high availability) LED is located in the front panel near the power status LED
of the LED dashboard. The LED lights when the router starts, but otherwise remains
unlit.Table 9 on page 16 describes the HA LED.
Table 9: J2320 and J2350 HA LED
Color
State
Green
On steadily
Red
On steadily
Amber
On steadily
Unlit
Off

RESET CONFIG Button

Use the
or to the factory default configuration, or a rescue configuration. The button is
recessed to prevent it from being pressed accidentally. For details about the
CONFIG
Inaccessible" on page 160.
16
J2320 and J2350 Services Router Hardware Features
State
On steadily
Off
Description
All cluster members and monitored links are available.
A cluster member is missing or unreachable, or the other node is no longer part of
a cluster because it has been disabled by the dual membership and detection
recovery process in reaction to a control link or fabric link failure.
All cluster members are present, but one or more monitored links are down.
The node is not configured for clustering or it has been disabled by the dual
membership and detection recovery process in reaction to a control link or fabric
link failure.
button to return the router to a previous valid configuration
RESET CONFIG
button, see "Resetting the Configuration File When the Router Is
Description
Minor alarm condition requires monitoring or maintenance:
Indicates a noncritical condition on the router that, if
left unchecked, might cause an interruption in service
or degradation in performance.
A missing rescue configuration or software license
generates an amber system alarm.
No alarms.