Troubleshooting Power Management
If one or more PIMs remain offline when you power on the chassis, the combination
of PIMs installed might exceed the power and heat capacity of the chassis. For
information about the maximum power and heat tokens permitted for each chassis,
see "Planning for Power Management" on page 72.
To bring the PIM online:
1.
NOTE: In the
reported as an FPC number.
2.
Check if the PIM exceeds the power and heat tokens permitted by issuing the
show chassis fpc
and
show chassis power-ratings
user@host> show chassis fpc
Temp
CPU Utilization (%)
Slot State
0 Online
-------------------- CPU less FPC --------------------
1 Online
-------------------- CPU less FPC --------------------
2 Online
-------------------- CPU less FPC --------------------
3
Empty
4
Empty
5 Offline
------ Hardware exceeds High Power token limits ------
In this example, J-series power management has placed the PIM in slot 5 in an
offline state to prevent damage. If brought online, the PIM would cause the
combination of PIMs to exceed the maximum limit of 83 high-power tokens for
the J2350 router.
user@host> show chassis power-ratings
Device
Low
High
Power
Total Tokens
83
FPC 1
6
FPC 2
3
FPC 3
3
FPC 4
0
FPC 5
2
Tokens Used
14
show chassis power-ratings
The offline PIM is not powered off and continues to draw minimal power.
To bring the PIM online, you have the following options:
Chapter 9: Troubleshooting a Services Router
CLI commands:
Memory
Utilization (%)
(C)
Total
Interrupt
Heat
Ratings
Power
83
83
-
27
21
OK
27
18
OK
27
18
OK
0
0
OK
27
2
Exceeded
108
59
-
command output, the PIM slot number is
Troubleshooting Hardware Components
DRAM (MB) Heap
Buffer
159