7845GSM/7845GSMCN Installation and Setup Guide
You will be instructed how to proceed upon completing the sign-up form. Only one sign-up
per dealer is required. Once an initial user is established, additional logins may be created
by that user.
NOTE: Central Stations sign up by contacting AlarmNet Administration at 800-222-6525
option 3.
Please have the following information available when programming the device:
1. Primary City ID (two-digit number)
2. Primary Central Station ID (two-digit hexadecimal number)
3. Primary Subscriber ID (four-digit number)
4. MAC ID and MAC CRC number (located on outside of box and on label inside
5. Mode of operation of existing module if replacing a "C" series radio.
Once module is registered, you may log out of the AlarmNet Direct website.

Using the Tamper Switch

Initiate the registration sequence by clicking the Tamper Switch three times.
You can monitor the registration process by viewing the Status Display.
(yellow) LED and the Status (green) LED will blink slowly in unison while registration is in
progress.
Once the registration has been completed successfully, the 7845GSM enters normal
operating mode; the Status (green) LED goes out and the Message (yellow) LED is lit to
indicate that the power-on / reset message is waiting to be sent. This message will appear at
the receiving station as "E339 8xx", where "xx" is the ECP device address. The description
may read "Trouble – Exp. Mod. Reset". If registration is not validated within 90 seconds,
the 7845GSM times out, and the (green) LED will be lit (solid).
The power-on/reset message will be sent in Ademco High-Speed format if the module is
programmed for zone trigger, 4204 or 2x4204 modes.

Using the Programming Tool

The interactive registration feature allows the installer to register the 7845GSM through a
series of keyboard commands on the 7720P Programming Tool. This method of registration
lets the installer monitor the registration process.
4-2
WWW.DIYALARMFORUM.COM
module) or MIN number of the device you are replacing.
Registering ...
Registration
SUCCESS
WWW.DIYALARMFORUM.COM
Once the installation is complete, press the [↑ ↑ ↑ ↑ ] key on
the 7720P. The registration message is sent and the
unit waits for the acknowledgment.
If this is a new installation and the city, central station,
and customer numbers have been correctly entered, the
7845GSM is registered and this message is displayed.
The 7845GSM is now in full service and available for
alarm reporting to the central station.
The Message