Storage And Transport Conditions; Field Of Application; How It Works; Technical Characteristics - Zodiac PF 11M Installation Instructions Manual

Heat pump for swimming pools
Hide thumbs Also See for PF 11M:
Table of Contents

Advertisement

1.1.3 Storage and transport conditions

The appliance must be transported upright on its pallet.

1.1.4 Field of application

Exclusive use: heating swimming pool water
It must not be used for anything else.

1.1.5 How it works

Air 15 °C
Temperatures for information

1.2 Technical characteristics

Single phase
PF
voltage
230V-50Hz
6M
8M
230V-50Hz
11M
230V-50Hz
13M
230V-50Hz
15M
230V-50Hz
* with an ambient air of +15 °C and a pool water of 26 °C, humidity 70% (in compliance with the French
NF-414 standard)
 unit protection class: IP 24
 refrigerant gas: R410A
 refrigerant charge: see product name plate
 class : I,
 degree of pollution : 2,
 overvoltage category : II

1.3 Operating conditions

Operating range:
 between 5 °C and 38 °C of air temperature
 between 5 °C and 32 °C of water temperature
Maximum temperature limited at 32°C to protect the pool liner.
Compressor
Air 10 °C
Expansion valve
condenstates
Power
Power
consumed*
restored*
kW
kW
1.3
6.4
1.6
7.3
2.2
10
2.8
12.1
3.1
14.5
Nominale
current
COP*
consumption*
A
6.25
4.7
7.3
4.5
10.5
4.6
13
4.3
15
4.7
Water 28 °C
Water 26 °C
Sound
Sound
pressure at
power*
10 meters*
dBA
dBA
65.3
37.3
65.2
37.2
66.7
38.7
65.1
37.1
65.1
37.1
3
EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp 8m

Table of Contents