1.1.3 Storage and transport conditions
The appliance must be transported upright on its pallet.
1.1.4 Field of application
Exclusive use: heating swimming pool water
It must not be used for anything else.
1.1.5 How it works
Air 15 °C
Temperatures for information
1.2 Technical characteristics
Power
Single
consumed*
PF
phase
voltage
6M
230V-50Hz
8M
230V-50Hz
11M
230V-50Hz
13M
230V-50Hz
230V-50Hz
15M
* with an ambient air of +15 °C and a pool water of 24 °C, humidity 70%
unit protection class: IP 24
refrigerant gas: R410A
refrigerant charge: see product name plate
class : I,
degree of pollution : 2,
overvoltage category : II
Compressor
Air 10 °C
Expansion valve
condenstates
Nominale
Power
current
restored*
consumption*
kW
kW
1.35
6.6
1.59
7.8
2.20
11
2.83
13.3
3.10
15.5
Sound
power*
COP*
A
dBA
6.25
4.9
65.3
7.3
4.9
65.2
10.5
5
66.7
13
4.7
65.1
15
5
65.1
Water 28 °C
Water 26 °C
Sound
pressure at
Weight
10 meters*
dBA
Kg
37.3
51
37.2
52
38.7
63
37.1
68
37.1
81
3
EN