6.5 Winter storage

• Press the button
appears.
Close the valves V2 and V3 of the BY-PASS.
Open valves V4 and V5 next to the unit
Drain the water condenser (RISK OF FROST) by unscrewing the two pool water inlet and outlet unions on the
side of the heat pump.
Lightly retighten the two unions to avoid any risk of foreign bodies entering the
Do not hermetically seal the unit (risk of condensation). A special-purpose ventilated cover is available (optional
accessory provided by PSA).

7. MAINTENANCE INSTRUCTIONS

Tasks to be carried out by a qualified and authorised person:
The following operations must be carried out at least once a year:
• Clean the evaporator at the back of the heat pump
- Never use a high-pressure cleaner for this operation -
• Check the settings.
• Check safety devices.
• Check the presence of refrigerant
• Check electrical connections and terminals
• Check earth connections.
• Do not use solvents to clean the outside of your unit, PSA NET offers an optional specific cleaning kit.
Before working on the appliance, ensure that the power supply is disconnected and secured. All interventions must be carried
out by persons who are qualified and authorised to work on this type of equipment .

8. RECYCLING THE PRODUCT

When replaced, this unit must be recycled by a specialised service or sent back to PSA.
to switch the regulation to
(if present)
Incorrect winter storage automatically cancels the GUARANTEE.
(check the pressure gauge needle with the compressor switched off).
This appliance contains a refrigerant and high-tech electrical components.
, Ofr5 is displayed for 5 s before a small red dot
«stand-by»
.
(with a soft brush and gentle water spray)
(retighten the supply cable terminals)
IMPORTANT
16
condenser.
.
.