POSITIONING THE APPLIANCE

For a safe and quiet operation, the furnace must be levelled in both directions. Give each "U" shape
block, an equal support so that the weight is evenly distributed.

PIPE CONNECTOR AND DAMPER

The pipe connecting the furnace to the chimney must be as short as possible. Whenever possible, the
o
use of 45
elbows is recommended for a better evacuation of the smoke in the chimney, for both the wood
burning furnace and the oil burning unit (UH). The barometric damper provided with the appliance must be
installed in the oil unit evacuation pipe, approximately 24" from the flue outlet of the oil unit.
TYPE OF FURNACE
PSG/UH 2000
PSG/UH 3000
PSG/UH 4000
PSG/UH 4500
PIPE DIAMETER
26
(UH) OIL
UNIT FLUE
5"
5"
5"
6"