Line Monitor Log - Furuno GS-100 Operator's Manual

Satellite speed log
Hide thumbs Also See for GS-100:
Table of Contents

Advertisement

3. SETTINGS
8. Select [7 User Priority].
Note 1: The default priority order is Data1 > Data2 > Data4. Data 3 port is not
available for serial input.
Note 2: When the heading data is input from CAN, CAN has the top priority.
9. Enter the priority for heading data by port number. For example, to set the priority
order as Data1, Data4, Data2, enter 1, 4, 2.
Note: The heading data calculated from the GS-1001 (CAN) has the top priority.
Then the heading data set above is used in order.
10. Move the cursor to [Enter] then press the ENT key.
11. Set the input data for [2 Ext. STW/COG/SOG] (external speed through water/
course over ground/speed over ground), [3 Ext. CUR] (external current), [4 Ext.
DEPTH] (external water depth) and [5 Ext. Wind] (external true wind speed and
angle) as well. Set these menus when the external input is available.
Note: [CAN] is available only for [HDG].
12. Press the MENU ESC key to close the main menu.
3.8.4

Line monitor log

Line monitor
1. Press the MENU ESC key to open the main menu.
2. Select [5 I/O] then [7 Line Monitor].