Motorola DCT6400 Phase III Installation Manual page 60

High-definition dvr cable terminal
Hide thumbs Also See for DCT6400 Phase III:
Table of Contents

Advertisement

4-28
Diagnostics
Figure 4-10
Interactive status LED display
The Interactive Status fields are:
Field
Description
IP Address
The IP address in dotted-decimal format xxx.xxx.xxx.xxx assigned by the NC 1500 to the
DCT6400. 0.0.0.0 is displayed if the IP address is not configured or unknown.
UPM
The upstream modem address value is the same as the terminal ID assigned by the
DAC 6000. It is a unique, system-generated, eight-digit integer between 1 and 16777215.
00000000 is displayed when the UPM is not configured or unknown.
Upstream ID
A four-digit decimal value from 0000 to 9999 assigned by the DAC 6000 to the DCT6400.
0000 is displayed if the Upstream ID is not configured or unknown.
Downstream ID
A four-digit decimal value from 0000 to 9999 assigned by the DAC 6000 to the DCT6400.
0000 is displayed if the Downstream ID is not configured or unknown.
State
The interactive status of the DCT6400:
LED
U
C
I dc
I L
I SO
I LA
S I
r dc
r
S
00
DCT6400 Phase III Installation Manual
MUTE
OSD
UNCONFIG
MAC_CONNECT
INIT_WAIT_DC_OR_C
WAIT_LM_ACK
WAIT_SO_ACK
WAIT_LA_OR_SO
INIT_STOPPED
RUN_WAIT_DC_OR_C
RUNNING
RUN_STOPPED
INVALID
P
P
MUTE
Description
The DCT6400 is not configured for the interactive
system and platform should run as pre-interactive.
The DCT6400 is waiting to establish connection to
MAC PID Stream.
The DCT6400 is in the interactive initialization state
and waiting for the default configuration or the
contention channel list messages.
The DCT6400 is in the interactive initialization state
and waiting for Link Management Response ACK for
Local Address Message.
The DCT6400 is in the interactive initialization state
and waiting for a Sign On acknowledgement.
The DCT6400 is in the interactive initialization state
and waiting for Logical Address or Sign On with
verification Frequency message.
The DCT6400 is in the interactive initialization state
and the TransMode has stopped.
The DCT6400 is in the interactive state and waiting for
the default configuration or the contention channel list
messages.
Interactive state is running, sending idle messages,
and waiting for any prepare for poll or MAC messages.
The interactive run state has stopped and DCT6400 is
waiting for status or transmission control message.
The interactive state is unknown or invalid.